{"product_id":"bmxcps4002-schneider-electric-modicon-m580-redundant-power-supply","title":"BMXCPS4002 Schneider Electric Modicon M580 Redundant Power Supply","description":"\u003ch2\u003eSCHNEIDER ELECTRIC BMXCPS4002 Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-availability power distribution in Modicon X80 and M580 platforms, the \u003cstrong\u003eSCHNEIDER ELECTRIC BMXCPS4002\u003c\/strong\u003e (\u003cstrong\u003eBMXCPS4002\u003c\/strong\u003e Redundant Power Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXCPS4002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eManufacturer specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.51 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard X80 module format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e40 W (Total output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC (85-264 VAC limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e15 W @ 3.3 VDC \/ 40 W @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e2300 Vrms (input to secondary)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and Performance\u003c\/h3\u003e\n\u003cp\u003eThe BMXCPS4002 serves as a foundational component for deterministic control architectures by ensuring stable DC output to the X-bus and Ethernet backplane modules. In redundant configurations, the processor utilizes firmware-managed load balancing, ensuring that the backplane bus communication velocity remains constant even during power supply switchover events. The module supports I\/O density scaling by providing high-capacity secondary power rails, allowing for larger M580 rack configurations without compromising signal integrity or logic execution timing. Diagnostic reporting via the \"Power OK\" relay ensures that the controller can proactively manage system state if an input voltage deviation occurs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the BMXCPS4002 support hot-swapping during active PLC operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, when deployed in a redundant configuration with a compatible BMEXBPxx02 backplane, this module supports hot-swapping. The redundant unit maintains power to the rack during the replacement process, ensuring no interruption to the PLC logic scan.\u003c\/p\u003e\n\u003cp\u003eQ: How should the \"Power OK\" relay be integrated into the control logic?\u003c\/p\u003e\n\u003cp\u003eA: The normally closed (NC) relay contact should be wired to a discrete input module on the rack. The logic should be configured to generate an alarm upon relay opening, indicating a loss of input power or a module fault, allowing for immediate maintenance intervention.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the rack is powered down before the initial installation of the power module. Slide the BMXCPS4002 into the designated power supply slot and secure it using the integrated locking mechanism.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect the 100-240 VAC source to the primary input terminals. Use appropriate gauge copper wire and ensure that the protective earth (PE) terminal is securely fastened to the cabinet ground bus to satisfy the 2300 Vrms isolation requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Upon power-up, confirm that the green \"Power OK\" LED is illuminated. Use a multimeter to verify the output voltage on the 24 VDC rails before mounting sensitive I\/O modules to the backplane.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":42870868115546,"sku":"BMXCPS4002","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/95._1126f410-4ceb-4360-8685-ba05c6f5c170.jpg?v=1772158773","url":"https:\/\/www.spareoil.com\/products\/bmxcps4002-schneider-electric-modicon-m580-redundant-power-supply","provider":"SpareOil Automation","version":"1.0","type":"link"}