{"product_id":"brand-new-3500-05-02-05-00-00-01-bently-nevada-mini-rack","title":"Brand New 3500\/05-02-05-00-00-01 Bently Nevada Mini Rack","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/05-02-05-00-00-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a compact, 12-inch hardware foundation for the industry-leading 3500 Series Machinery Protection System. While the full-size 19-inch rack accommodates 14 modules, this 7-slot Mini Rack targets smaller machinery trains and installations with restricted cabinet space. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, ensuring a pristine passive backplane for critical data communication between monitors and the Rack Interface Module (RIM). It complies fully with API 670 standards, offering specialized protection for pumps, motors, and smaller compressors.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/05 rack uses a specific dash-code structure to define mounting and approval options:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3500\/05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 System Rack Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-inch Mini-Rack (7 slots)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple Approvals (CSA\/NRTL\/C, ATEX, CE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo internal barriers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Backplane (No TMR)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRack Mount Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis rugged aluminum and steel chassis supports the following environmental and mechanical parameters:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSlot Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 Monitoring Slots + Power Supply \u0026amp; RIM Slots\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive digital communication\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19-inch EIA Standard Rail (via Rack Mount Adapter)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-inch (approx. 305 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 °C to +65 °C (-22 °F to +150 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial-grade aluminum and steel alloys\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.0 kg (13.2 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCSA, ATEX, CE, NRTL\/C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Spatial Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 12-inch design solves the industrial pain point of overcrowded control cabinets. Engineers can deploy full Bently Nevada protection in smaller junction boxes where a standard 19-inch rack would not fit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectromagnetic Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe aluminum and steel alloy construction acts as a Faraday cage, shielding internal monitoring modules from high-frequency electromagnetic interference (EMI) common in power generation and motor control centers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePassive Backplane Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe chassis utilizes a passive backplane, meaning the rack itself contains no active electronic components that could fail. This design maximizes the Mean Time Between Failures (MTBF) for the entire machinery protection system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAPI 670 Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis chassis meets the rigorous requirements for vibration, temperature, and thrust monitoring of critical assets, ensuring the system remains the gold standard for high-risk industrial insurance and safety audits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use a standard 3500 Power Supply in this Mini Rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 3500\/05 Mini Rack features a dedicated slot for standard 3500 Series Power Supply modules. However, ensure your power calculations account for the 7-slot maximum draw to maintain thermal efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the -01 and -02 mounting options?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe -02 option signifies the physical 12-inch Mini Rack chassis size. The final -01 suffix in this specific model indicates it includes the hardware necessary for Rack Mounting within a standard cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this rack support Triple Modular Redundancy (TMR)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific configuration (00 in the fifth position) uses a standard backplane. For TMR applications, a different backplane version is required. Please verify your system architecture requirements before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the rack handle grounding for signal integrity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe chassis features reinforced insulation between the backplane and the frame, allowing engineers to maintain a clean signal ground, which is essential for accurate vibration readings at low amplitudes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870903046234,"sku":"3500\/05-02-05-00-00-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/347_34f3a10d-232b-4699-9ae2-a93af8b7d98a.jpg?v=1771986496","url":"https:\/\/www.spareoil.com\/products\/brand-new-3500-05-02-05-00-00-01-bently-nevada-mini-rack","provider":"SpareOil Automation","version":"1.0","type":"link"}