{"product_id":"brand-new-bently-nevada-3500-92-modbus-rtu-interface","title":"Brand New Bently Nevada 3500\/92 | Modbus RTU Interface","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/92-02-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the primary data bridge between the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500 Machinery Protection System\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand external control networks. This Communication Gateway module collects critical machine data—such as vibration levels, axial position, speed, and alarm statuses—from the rack backplane and translates it into standard Modbus protocols. By providing a secure, high-speed digital link to DCS, PLC, or SCADA systems, the 3500\/92 ensures that plant operators maintain full visibility of rotating asset health from the central control room. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original in Factory Packing\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: 3500\/92-AA-BB-CC\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Module Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus RS485 I\/O Module (Serial)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMemory Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow Memory Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone (Standard Industrial)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus RTU (via RS-485 Serial)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Independent Serial Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBaud Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConfigurable (Up to 19.2 kbps)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to +140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 Vdc Galvanic Isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRack Slot Occupancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOne Full-height Slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 Watts Typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.82 kg (Shipping weight2 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, CSA, SIL3 System Compliant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Third-Party Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 3500\/92-02-01-00 eliminates the need for complex hard-wiring of individual analog outputs. It transmits hundreds of static and status variables over a single RS-485 serial link, drastically reducing installation costs and cabinet wiring density.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Port Redundancy\/Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features two serial ports. This allows engineers to connect the 3500 rack to two independent systems simultaneously (e.g., a DCS for control and a separate SCADA for historical data logging) without signal interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in galvanic isolation protects the 3500 rack backplane from external electrical surges or ground loops common in industrial RS-485 networks. This ensures that a fault on the communication bus does not compromise the machinery protection logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Memory Mapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe Low Memory (01) configuration provides a streamlined data map, optimizing the polling speed for standard Modbus masters. This ensures that the external control system receives alarm updates and status changes with minimal latency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou can replace the 3500\/92 module while the rest of the rack remains energized. Since the gateway handles monitoring data and not the actual trip logic, swapping this module does not interfere with the primary machinery protection functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module to send data to a 3500\/94 Display Router?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 3500\/92 is specifically for Modbus communication with external devices (DCS\/PLC). The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/94\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a separate module designed to drive the local VGA display. They operate independently on the system bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 3500\/92-02-01-00 support Ethernet (Modbus\/TCP)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific part number (Option 02) is for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS-485 Serial\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommunication. If your system requires Ethernet connectivity (Modbus\/TCP), you would typically require the 3500\/92-04-01-XX configuration. Always verify your site’s communication infrastructure before ordering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the Modbus register map?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfiguration occurs through the Bently Nevada 3500 Rack Configuration Software. You can define which machinery parameters are mapped to specific Modbus registers to match your DCS database requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the condition of this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee that the 3500\/92-02-01-00 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e. It ships in its original Bently Nevada factory-sealed packaging with a full 12-month warranty.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43190485123162,"sku":"3500\/92-02-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/425._31f8d681-2580-4ec1-9f4d-8c4829da666d.jpg?v=1775613893","url":"https:\/\/www.spareoil.com\/products\/brand-new-bently-nevada-3500-92-modbus-rtu-interface","provider":"SpareOil Automation","version":"1.0","type":"link"}