{"product_id":"brand-new-ic693mdl930-isolated-output-module-series-90-30","title":"Brand New IC693MDL930 Isolated Output Module Series 90-30","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC693MDL930\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-versatility discrete output interface for the Series 90-30 PLC platform. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule features eight independent, normally open (Form A) mechanical relay channels. Unlike standard common-return modules, the IC693MDL930 provides total electrical isolation for every point. This unique architecture allows a single module to control diverse field devices operating at different voltage potentials—such as 240 VAC motors and 24 VDC pilot lights—simultaneously without cross-talk or the need for interposing relays.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIsolated Discrete Relay Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Channels (Normally Open \/ Form A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAC Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 VAC \/ 240 VAC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDC Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 VDC \/ 24 VDC \/ 125 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 Amps maximum per point (resistive)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 VAC RMS (Channel-to-Channel \u0026amp; Channel-to-Logic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 ms Maximum (On\/Off)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Load\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMechanical Life\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 Million Operations (No Load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Green LEDs (Logic side status)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Power Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 mA (5V bus) \/ 70 mA (24V relay bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMixed Voltage Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual channel isolation eliminates the requirement for multiple output modules or external isolation barriers. You can wire different power sources to each of the eight points safely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Voltage DC Switching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile many standard modules struggle with high DC voltages, the IC693MDL930 handles up to 125 VDC nominal, making it ideal for utility and power substation applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1500 VAC isolation barrier prevents transient noise from the field wiring from entering the PLC backplane, protecting the CPU and sensitive logic components from damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInductive Load Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe robust mechanical contacts withstand the inrush currents typical of solenoids, contactors, and small motors, reducing the frequency of hardware failure in heavy-duty cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZero-Leakage Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMechanical relays offer a true \"dry contact\" physical break, ensuring zero leakage current in the \"OFF\" state—a critical safety advantage over solid-state Triac or Transistor outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC693MDL930 handle both AC and DC on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eYes. Because each of the 8 channels is physically isolated from the others, you can switch an AC load on Point 1 and a DC load on Point 2 without any risk of a short circuit between the two power sources.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external suppression for inductive loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhile the contacts are robust, we strongly recommend installing external RC snubbers for AC loads or diodes for DC loads to extend the mechanical life of the relays when switching highly inductive devices like large contactors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"Isolated\" designation mean for wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIt means there is no \"Common\" terminal. Each of the 8 outputs has two dedicated screw terminals (A and B), ensuring complete circuit independence for every field device connected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module a direct replacement for older 90-30 relay modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe IC693MDL930 is a standard Series 90-30 module. If your application currently uses a non-isolated module (like the MDL940), you will need to verify your field wiring, as the terminal assignments differ to accommodate individual channel isolation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42870900818010,"sku":"IC693MDL930","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/182_76cdec95-8a54-4f83-8189-1abeaee1dba0.jpg?v=1771056947","url":"https:\/\/www.spareoil.com\/products\/brand-new-ic693mdl930-isolated-output-module-series-90-30","provider":"SpareOil Automation","version":"1.0","type":"link"}