{"product_id":"buy-ge-fanuc-ic200chs006-communication-carrier-original","title":"Buy GE Fanuc IC200CHS006 Communication Carrier Original","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IC200CHS006\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the essential backbone for the VersaMax I\/O system, acting as both a mechanical mounting base and a high-speed electrical interface. This communication carrier facilitates seamless data exchange between I\/O modules and the PLC backplane while providing secure termination for field devices. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring peak performance for your manufacturing and process control infrastructure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36 IEC-style screw terminals (A1–A18, B1–B18)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Data Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 244 bytes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Baud Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.6 Kbaud to 12 Mbaud\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 VDC (Backplane) \/ Supports 0–264 VAC Field Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 mA (Internal) \/ 2 A per point (Field)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm x 7.5 mm DIN rail or Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWiring Gauge\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAWG #14 to #22 (Solid or Stranded)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C (Standard) \/ -40°C to +70°C (Extreme Range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Data Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200CHS006 supports a broad network baud rate up to 12 Mbaud. This allows the carrier to handle complex, high-density data packets (up to 244 bytes) without causing latency in distributed control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Efficient Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact \"box-style\" architecture reduces footprint requirements within the electrical cabinet. Engineers can maximize I\/O density by snapping these carriers directly onto a standard 35mm DIN rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTool-less Backplane Setup:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated carrier-to-carrier connectors establish the internal communication bus instantly. This \"click-and-connect\" design eliminates external ribbon cables, significantly reducing assembly time and potential failure points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Electrical Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit tolerates voltage transients up to 300 VAC. This protection layer prevents field-side electrical noise and surges from damaging the sensitive PLC logic circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA built-in wiring card holder provides immediate visual reference for field technicians, accelerating maintenance and reducing the risk of wiring errors during module swaps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the IC200CHS006 compatible with both standard and extended temperature environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. While standard operation covers 0°C to 60°C, the ruggedized design permits storage and specialized operation in environments ranging from -40°C to +70°C, making it suitable for unconditioned utility enclosures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this carrier for high-speed PROFIBUS or Genius network modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Absolutely. This communication carrier specifically supports the high-speed backplane requirements (up to 12 Mbaud) necessary for advanced communication interface modules within the VersaMax family.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this unit require a specific type of wiring for the IEC terminals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The IC200CHS006 accommodates both solid and stranded copper wire. For dual-wire connections, use AWG #18. For single-wire runs, the terminals accept a range from AWG #14 to #22, providing high flexibility for different field device requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the carrier ensure EMC protection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The carrier utilizes the DIN rail as a primary grounding path. To ensure proper shielding and EMC compliance, you must mount the carrier on a grounded, conductive (zinc-plated) DIN rail.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43289736314970,"sku":"IC200CHS006","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/22_fdbafc66-c19f-4388-a739-fae8d7054354.jpg?v=1777446559","url":"https:\/\/www.spareoil.com\/products\/buy-ge-fanuc-ic200chs006-communication-carrier-original","provider":"SpareOil Automation","version":"1.0","type":"link"}