{"product_id":"cc-mcarw1-honeywell-galvanic-isolation-carrier-channel","title":"CC-MCARW1 Honeywell Galvanic Isolation Carrier Channel","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-MCARW1 serves as a high-integrity Galvanic Isolation \/ Intrinsically Safe (GI\/IS) Carrier Channel Assembly within the Experion PKS Series C architecture. This 100% brand-new, original unit functions as the structural and electrical foundation for Series C I\/O modules, specifically those requiring intrinsic safety barriers. By providing the essential backplane connectivity and power distribution interface, the CC-MCARW1 ensures stable data transmission between field instrumentation and the controller while maintaining strict isolation standards in hazardous area applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe CC-MCARW1 utilizes industrial-grade materials to support the heavy-duty requirements of Series C cabinet installations.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCC-MCARW1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAssociated Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51403892-100 (Core Base)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGI\/IS Carrier Channel Assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell Experion PKS Series C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanic Isolation \/ Intrinsically Safe Interfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertical Series C Carrier Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC (System Backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to +60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNew \u0026amp; Original in Factory Packing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-MCARW1 addresses the complexities of hazardous area signal management through specialized mechanical and electrical design:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified GI\/IS Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis carrier assembly eliminates the need for separate, bulky DIN-rail mounted barriers. By integrating the isolation channel directly into the Series C footprint, the CC-MCARW1 significantly reduces cabinet wiring complexity and saves valuable rail space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe assembly features precision-engineered backplane connectors that minimize contact resistance. Consequently, the module maintains superior signal clarity for sensitive low-level analog inputs and intrinsically safe digital signals, even in high-interference environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Thermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell designed the carrier to facilitate natural convection cooling across the mounted I\/O modules. This airflow management prevents localized hotspots, thereby extending the MTBF (Mean Time Between Failures) of the active electronics installed on the base.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration-Resistant Locking:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CC-MCARW1 incorporates a secure mechanical latching system that locks modules firmly into place. This design prevents intermittent connectivity issues caused by mechanical vibration or thermal expansion, ensuring continuous uptime in heavy industrial processing zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between CC-MCARW1 and the standard CC-MCAR01?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CC-MCARW1 specifically supports GI\/IS (Galvanic Isolation\/Intrinsically Safe) configurations. While they share a similar physical form factor, the \"W\" variant includes specific internal bus routing and isolation clearances necessary for safe operation in hazardous area loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install standard Series C I\/O modules on this carrier?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe carrier accepts modules designed for the Series C GI\/IS interface. Always verify that your specific I\/O module and IOTA (Input Output Termination Assembly) pair match the electrical specifications of the carrier base to ensure proper system performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the CC-MCARW1 include the I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The CC-MCARW1 is a passive carrier assembly that provides the mounting base and communication bus. You must purchase the active I\/O modules and the appropriate IOTA separately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this assembly suitable for corrosive environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CC-MCARW1 meets standard Series C industrial specifications. For facilities with high concentrations of corrosive gases, we recommend ensuring that the modules installed on the carrier feature G3 conformal coating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43242421518426,"sku":"CC-MCARW1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/205_6a5e9686-c391-4464-9c47-71d1bb6c22c8.jpg?v=1776666540","url":"https:\/\/www.spareoil.com\/products\/cc-mcarw1-honeywell-galvanic-isolation-carrier-channel","provider":"SpareOil Automation","version":"1.0","type":"link"}