{"product_id":"chassis-power-supply-120v-6a-5v-24v-honeywell-51195066-100","title":"Chassis Power Supply 120V 6A 5V\/24V | Honeywell 51195066-100","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51195066-100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a multi-output industrial power supply unit specifically engineered for Honeywell TDC 3000 and Experion PKS control chassis. As an authoritative power source for mission-critical automation, this module provides the diverse voltage rails required to energize controllers, high-density I\/O modules, and backplane logic. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51195066-100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a mechanical necessity for systems requiring synchronized time-stamping, featuring jumper-selectable clock configurations for Sequence of Events (SOE) functionality. Designed for continuous service in refineries and power generation facilities, it delivers high-current 5VDC and 24VDC outputs to maintain the electrical integrity of distributed control system nodes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003e(Note: Technical correction applied—the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51195066-100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a multi-rail chassis supply featuring four distinct DC outputs to support legacy and modern backplane logic.)\u003c\/em\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e51195066-100\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-Slot Chassis Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 \/ 240 VAC (Auto-sensing\/Selectable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47–63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.0A (at 120V) \/ 3.75A (at 240V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDC Output 1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 VDC at 30.0 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDC Output 2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+12 VDC at 8.0 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDC Output 3\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-12 VDC at 1.0 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDC Output 4\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+24 VDC at 1.0 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOriginal 8-pin high-current interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eClock Sync\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJumper selectable (Internal Line Freq or External Source)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to +85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL, Industrial Compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePre-Installation Verification\u003c\/strong\u003e: Ensure the input voltage selector (if applicable) matches the 120V or 240V site power. Confirm the module is a trustworthy replacement for discontinued units like 51400712-100.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Alignment\u003c\/strong\u003e: Align the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51195066-100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith the dedicated power supply slot in the Honeywell 5-slot chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeating and Securing\u003c\/strong\u003e: Push the module firmly into the backplane until the 8-pin connector is fully engaged. Secure the module using the chassis retention screws to maintain a trustworthy electrical bond against industrial vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClock Configuration\u003c\/strong\u003e: Before power-up, set the internal jumper for clock synchronization. For systems utilizing Sequence of Events (SOE), align the jumper with the site's master clock requirements (Line Frequency or External).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower-Up Sequence\u003c\/strong\u003e: Apply AC power and verify the front-panel LED indicators. A successful installation is confirmed when all status lights indicate active DC rails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Procedure\u003c\/strong\u003e: If replacing a module in a redundant configuration, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51195066-100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan be swapped without powering down the entire chassis, a mechanical necessity for 24\/7 uptime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat systems are compatible with the 51195066-100?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is primarily designed for the Honeywell TDC 3000 High-Performance Process Manager (HPM) and Experion PKS chassis that require a multi-rail supply for legacy backplane support.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support Sequence of Events (SOE) recording?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51195066-100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an authoritative component for SOE, as it provides the line-frequency clock synchronization signal across the chassis backplane when the internal jumper is correctly configured.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 30A rating on the 5V rail affect performance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 30A capacity on the 5VDC rail is a mechanical necessity for powering fully populated 5-slot chassis containing high-speed processors and dense communication modules, ensuring a trustworthy voltage level under peak load.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43067591753818,"sku":"51195066-100","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/304..jpg?v=1773907875","url":"https:\/\/www.spareoil.com\/products\/chassis-power-supply-120v-6a-5v-24v-honeywell-51195066-100","provider":"SpareOil Automation","version":"1.0","type":"link"}