{"product_id":"controledge-900-safety-processor-honeywell-900c50s-0460","title":"ControlEdge 900 Safety Processor | Honeywell 900C50S-0460","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 900C50S-0460\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estands as the premier safety-certified processor for the ControlEdge HC900 automation platform. This SIL-2 safety-rated CPU module executes both critical safety interlocks and standard regulatory process control within a single, unified hardware environment. It manages complex logic, PID loops, and high-speed sequencing while adhering to strict safety integrity requirements. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, providing the hardware foundation necessary for burner management systems (BMS), emergency shutdowns (ESD), and critical process safeguarding.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e900C50S-0460-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL-2 Certified (Safety Instrumented System)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlEdge 900 High-Performance CPU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual Ethernet (Modbus TCP\/IP), Serial (Modbus RTU)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple Racks (8-slot and 12-slot)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-volatile Flash for Secure Logic Storage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e137mm H x 38.1mm W (5.4\" H x 1.5\" W)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.36 kg (0.79 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail (Within HC900 I\/O Racks)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial-grade thermal and EM resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Safety \u0026amp; Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 900C50S-0460 eliminates the need for separate safety and process controllers. It executes SIL-rated safety functions alongside standard control tasks, reducing hardware costs and simplifying the communication interface between safety and process layers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Safety Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module processes critical safety interlocks with high-speed execution cycles. This rapid response ensures that your system reaches a predetermined safe state immediately upon detecting a hazardous process excursion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure Non-Volatile Memory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDedicated non-volatile storage protects the safety configuration and application code. This safeguards the system against program corruption during power fluctuations, ensuring the safety logic remains valid and ready for execution upon restart.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis CPU supports redundant configurations to achieve high system availability. In a redundant setup, the backup CPU monitors the primary unit and assumes control instantaneously if a fault occurs, preventing nuisance trips in continuous process industries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated self-testing routines continuously monitor the CPU's internal health. The module identifies hardware failures in real-time and alerts operators through the HC900 diagnostic network, allowing for proactive maintenance before safety is compromised.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat distinguishes the 900C50S-0460 from a standard C50 CPU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"S\" designation indicates a Safety-rated version. The 900C50S-0460 undergoes rigorous SIL-2 certification, making it suitable for Safety Instrumented Systems (SIS), whereas the standard C50 is intended for regulatory control only.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs special software required for safety configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You must use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell HC Designer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith safety-enabled libraries to configure the SIL-rated logic. The software enforces specific safety protocols to ensure compliance with SIL-2 standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module in a non-safety application?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the 900C50S-0460 can execute standard control functions, its primary value lies in its safety certification. For applications that do not require SIL-2 ratings, a standard C50 or C70 module may be more cost-effective.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do you guarantee the condition of the CPU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee this\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900C50S-0460\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand ships in its original, factory-sealed Honeywell packaging. Every unit includes a full 12-month professional warranty.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43213676019802,"sku":"900C50S-0460","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/465.1_94b551ac-20e4-4b98-b71a-f98ebaa9835f.jpg?v=1776136249","url":"https:\/\/www.spareoil.com\/products\/controledge-900-safety-processor-honeywell-900c50s-0460","provider":"SpareOil Automation","version":"1.0","type":"link"}