{"product_id":"cp461-10-s1-yokogawa-centum-cs-3000-cpu-module","title":"CP461-10 S1 Yokogawa CENTUM CS 3000 CPU Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CP461-10 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eC2ND10029H\u003c\/strong\u003e) serves as the central processing unit and primary intelligence for Field Control Units (FCU) within the CENTUM CS 3000 and CENTUM VP distributed control systems. This high-performance module executes complex automation logic, governs I\/O signal management from field instrumentation, and maintains deterministic control over mission-critical processes. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e, ensuring your control architecture utilizes the high-integrity logic solver required for refinery, power generation, and chemical processing operations. Its Style S1 hardware revision optimizes system-wide coordination and ensures rapid execution of safety and control strategies.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe CP461-10 S1 follows Yokogawa's modular architecture for mission-critical DCS hardware:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Component\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCP461\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model: Processor Module for Field Control Stations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRevision Suffix: Standard high-performance CPU configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eS1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStyle Designation: Hardware revision S1 for specific backplane\/firmware compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eC2ND10029H\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturing identification\/Internal part number\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe CP461-10 S1 integrates high-speed logic solving with industrial-grade data protection:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCP461-10 S1 (Style S1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa Electric Corporation (Japan)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCentral Processing Unit for Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCENTUM CS 3000 and CENTUM VP Platforms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Battery Backup (Up to 72 Hours)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28.8 W (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (±10%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 °C to +70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 × 85 × 60 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Real-Time Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CP461-10 S1 prioritizes automation logic and I\/O signal processing over background tasks. This architecture ensures that PID loops and safety interlocks execute with consistent scan times, eliminating control \"jitter\" even during high network communication loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFail-Safe Data Retention:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn integrated battery backup safeguards the main memory during unexpected power interruptions. This protection maintains system data and critical process variables for up to 72 hours, allowing the system to perform a rapid \"warm start\" upon power restoration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Multi-Platform Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned as a bridge between generations, the CP461-10 S1 operates natively in both legacy CENTUM CS 3000 and modern CENTUM VP environments. This allows facilities to upgrade their processing power without requiring a complete system overhaul.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Industrial Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features a robust architecture engineered for the stresses of unconditioned field control rooms. It functions reliably across an expanded temperature range of -20 °C to +70 °C, ensuring long-term operational stability in remote or harsh locations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an older Style S0 module with the CP461-10 S1?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Style S1 is generally backward compatible with the same FCU baseplates. However, you should verify your current software revision (CS 3000 or VP) to ensure the system recognizes the updated revision level and diagnostic registers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I replace the memory backup battery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYokogawa recommends testing the battery status during annual maintenance. For mission-critical systems, we advise replacing the battery every 2 to 3 years to guarantee the full 72-hour data retention period.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support dual-redundant configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. When installed in a duplexed Field Control Unit, two CP461-10 S1 modules operate in a hot-standby configuration. The system synchronizes data in real-time, facilitating an instantaneous, bumpless failover if the primary unit detects a fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43116833767514,"sku":"CP461-10 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/126._4fa78c81-96b1-4fb1-9789-275ffaa107d6.jpg?v=1774417361","url":"https:\/\/www.spareoil.com\/products\/cp461-10-s1-yokogawa-centum-cs-3000-cpu-module","provider":"SpareOil Automation","version":"1.0","type":"link"}