{"product_id":"cp701-s1-yokogawa-processor-module-new-original-stock","title":"CP701 S1 Yokogawa Processor Module | New \u0026 Original Stock","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eYokogawa CP701 S1 Field Control Processor Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for process control and DCS instrumentation in CENTUM CS 1000 \/ CS 3000 \/ CENTUM VP systems, the \u003cstrong\u003eYokogawa CP701 S1\u003c\/strong\u003e (\u003cstrong\u003eYokogawa CP701\u003c\/strong\u003e Processor Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP701 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e26 cm x 6 cm x 28 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal loop draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Architecture\u003c\/td\u003e\n\u003ctd\u003eProprietary high-speed microprocessor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003eExpanded program execution and data storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP, ESB Bus, Ethernet 100Base-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Integration\u003c\/td\u003e\n\u003ctd\u003eFOUNDATION Fieldbus, PROFIBUS, DeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eField Control Station (FCS) rack-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to +75 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Layering\u003c\/h3\u003e\n\u003cp\u003eThe processing module interfaces directly with host Field Control Stations via Vnet\/IP networks to manage real-time loop synchronization. The architectural engine processes complex PID loops and sequential logic matrices across active 4-20 mA HART loop protocol branches without introducing processing lag. By utilizing a dedicated ESB bus backbone, the unit enforces strict channel-to-channel isolation parameters to shield internal registers from field-side voltage disturbances. Fieldbus couplers route digital process variables directly into the localized execution table, while built-in error-correction code memory actively scans and fixes internal bit inversions to prevent safety loop drops or loss of control tracking.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the processor module handle dual-redundant tracking and switchover latencies?\u003c\/p\u003e\n\u003cp\u003eA: When you configure dual CP701 S1 modules in a redundant Field Control Station layout, the primary unit continuously mirrors its memory registers to the backup processor over the backplane bus. If the active unit encounters a hardware fault, the secondary processor assumes control of the 4-20 mA HART loop protocol pathways without disturbing the active control outputs.\u003c\/p\u003e\n\u003cp\u003eQ: What are the backplane load limitations and power distribution bounds for this specific processor?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on a stabilized 24 VDC input supply routed through the FCS backplane. You must calculate the aggregate power requirement for all integrated communication cards and internal logic components to ensure total system current remains within the baseline power supply boundaries.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment and Connector Seating:\u003c\/strong\u003e Lower the processor card into the designated slot guides within the Field Control Station rack assembly. Push the module forward until the rear pins connect with the motherboard backplane, then lock the mechanical levers to secure the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Interface Cable Shielding:\u003c\/strong\u003e Route all Vnet\/IP and ESB bus lines inside separate low-noise cable tracks away from high-voltage motor starters, power lines, and variable frequency drive cables. Ground all external communication shields to the main control panel cabinet grounding bar.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Corridor Management:\u003c\/strong\u003e Verify that cabinet cooling fans and vertical airflow channels remain unblocked. You must maintain internal cabinet temperatures between -10 and +55 deg C to prevent localized heat build-up on the microprocessor components.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43510478798938,"sku":"CP701","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/386._c790e31b-cd6d-4291-873f-4b6319e7b822.jpg?v=1781744232","url":"https:\/\/www.spareoil.com\/products\/cp701-s1-yokogawa-processor-module-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}