{"product_id":"cpc210-bachmann-cpu-processor-module-new-original-stock","title":"CPC210 Bachmann CPU Processor Module | New \u0026 Original Stock","description":"\u003ch2\u003eBachmann CPC210 M1 Automation System\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBachmann CPC210\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCPC210\u003c\/strong\u003e CPU Processor Module, operates as a dedicated hardware component for control logic execution within Bachmann M1 Automation System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCPC210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria \/ Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 mm x 100 mm x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003e32-bit RISC processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock Speed\u003c\/td\u003e\n\u003ctd\u003e200 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Memory\u003c\/td\u003e\n\u003ctd\u003e64 MB SDRAM, 16 MB Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating System\u003c\/td\u003e\n\u003ctd\u003eBachmann real-time OS (VxWorks architecture)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003e2x Ethernet (10\/100 Mbit), 1x RS-232, 1x CAN bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Routing and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe processor module utilizes an integrated system architecture to establish low-latency communication via internal high-velocity backplane bus communication pathways. This localized interface logic enforces microsecond-level synchronization across neighboring input\/output channels, preventing signal jitter when executing motion trajectories or fast sequence loops. This high-density backplane interface optimizes total I\/O density scaling options while ensuring absolute firmware flash compatibility between peripheral functional cards and the central real-time VxWorks kernel.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the processor handle peripheral configuration changes during an active firmware flash sequence?\u003c\/p\u003e\n\u003cp\u003eA: An active firmware flash requires the processor to transition out of execution mode into a safe standby state. Peripheral I\/O modules connected across the high-velocity backplane will drop to predefined safe values until the master boot block reinitializes.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum current load limit this module can draw from the 24 VDC bus input?\u003c\/p\u003e\n\u003cp\u003eA: The central processor assembly has a nominal power consumption of approximately 10 W at 24 VDC. Auxiliary module additions across the backplane bus will scale the total system power consumption metrics and must be calculated against the main supply limits.\u003c\/p\u003e\n\u003cp\u003eQ: Does the CAN bus interface require independent physical termination at the module connector?\u003c\/p\u003e\n\u003cp\u003eA: Yes. When utilizing the embedded CAN bus interface for networking field devices, a standard 120 Ohm termination resistor must be physically installed across the terminal pins at the end points of the network line.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Alignment Matrix:\u003c\/strong\u003e Insert the module along the chassis tracking grooves until the internal multi-pin backplane bus adapter locks with the connector interface to prevent pins from bending.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Matrix:\u003c\/strong\u003e Clamp all Ethernet and CAN bus communications cables directly to the master copper ground terminal rail at the cabinet entrance to mitigate high-frequency interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparation of Power Circuits:\u003c\/strong\u003e Route the 24 VDC processor supply conductors in wiring ducts separated from 400 VAC motor leads or variable frequency drive cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow Clearance Boundaries:\u003c\/strong\u003e Maintain a minimum 50 mm free space envelope above and below the module assembly to allow correct convection airflow over the internal heat sinks.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43431344046170,"sku":"CPC210","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/291_10a9c5dd-b6c8-4845-a67d-b76bdf309295.jpg?v=1780021823","url":"https:\/\/www.spareoil.com\/products\/cpc210-bachmann-cpu-processor-module-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}