{"product_id":"csc3huwc2b2-woodward-seg-controller-module-new-original-stock","title":"CSC3HUWC2B2 Woodward SEG Controller Module | New \u0026 Original Stock","description":"\u003ch2\u003eWoodward CSC3HUWC2B2 SEG Controller Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward CSC3HUWC2B2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCSC3HUWC2B2\u003c\/strong\u003e Controller Module, operates as a dedicated hardware component for precise engine, turbine, and current sensing processing tasks within Woodward SEG control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCSC3HUWC2B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 - 1.2 kg (variant dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 x 100 x 60 mm \/ 160 x 100 x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e8 channels (0-10 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e16 channels (24 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT Inputs\u003c\/td\u003e\n\u003ctd\u003e3-phase current transformer inputs (1 A \/ 5 A nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003eUp to 120 A (scaled via CT ratio)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.5% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2.5 kV AC (CT to system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eActuator Loop Feedback Response\u003c\/h3\u003e\n\u003cp\u003eThe electronic architecture incorporates dedicated processing pathways optimized for sub-millisecond actuator loop feedback response. Current inputs derived from the 3-phase sensing circuit are converted via internal instrumentation networks to suppress electrical noise. Custom thermal heat sink dissipation profiles stabilize the internal measurement components, preventing measurement drift across the nominal 24 VDC excitation structure during high ambient temperature excursions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the isolation threshold between the current transformer inputs and the internal processing logic?\u003c\/p\u003e\n\u003cp\u003eA: The hardware platform provides galvanic isolation rated at 2.5 kV AC between the secondary CT measurement terminals and the internal system backplane components.\u003c\/p\u003e\n\u003cp\u003eQ: How does the unit process high-current transients during electrical faults?\u003c\/p\u003e\n\u003cp\u003eA: The input conditioning stage handles scaled overcurrent signals up to 120 A via external CT ratios, digitizing the waveform with a response delay of less than 5 ms to allow downstream protection execution.\u003c\/p\u003e\n\u003cp\u003eQ: What onboard diagnostics are present for local troubleshooting?\u003c\/p\u003e\n\u003cp\u003eA: The faceplate features dedicated diagnostic LED indicators that report internal module fault sequences and line-side connection discontinuities without requiring external software links.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Restrictions:\u003c\/strong\u003e Fit the housing securely onto standard DIN rails or dedicated sub-rack frames, ensuring proper spatial separation to allow unrestricted vertical airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCT Termination Security:\u003c\/strong\u003e Ensure external current loops are shorted using an external shorting block before disturbing terminal connections to eliminate dangerous open-circuit voltage spikes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Topology:\u003c\/strong\u003e Terminate the outer shields of all measurement and analog signaling wires directly at the incoming enclosure bulkhead ground rail, avoiding loops or ungrounded drain endpoints.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Fastening:\u003c\/strong\u003e Use calibrated torque tools to clamp wire terminations to the specified engineering limits, mitigating the risk of intermittent contacts or thermal expansion failures under field conditions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":43431319371866,"sku":"CSC3HUWC2B2","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/283_3a7b00f2-d9c7-49ad-a98c-32052aed87cc.jpg?v=1780017395","url":"https:\/\/www.spareoil.com\/products\/csc3huwc2b2-woodward-seg-controller-module-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}