{"product_id":"dai-01-abb-freelance-dcs-analog-input-module","title":"DAI 01 ABB Freelance DCS Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ABB DAI 01 functions as a high-precision, rack-based analog input module engineered explicitly for the ABB Freelance Distributed Control System (DCS) and its native I\/O architectures. As a core component of the Analog Input V3 series, this card reads critical real-time process variables—such as pressure, temperature, flow rate, and liquid level—by converting standard field instrument analog signals into clean digital data. It slots directly into standard ABB Freelance rack enclosures to provide centralized, high-density I\/O preprocessing.\u003c\/p\u003e\n\u003cp\u003eWe guarantee this module arrives 100% Brand New, original, and factory-certified to ensure deterministic loop performance across your plant control layers.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDAI 01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries Generation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Input V3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB Freelance DCS \/ Rack-Based I\/O Platforms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Input Density\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Analog Input Channels (Standard Configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Configurations\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent (0 to 20 mA, 4 to 20 mA) \/ Voltage (0 to 10 V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Conversion Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-bit to 16-bit (Software Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClass 0.1 percent of Full Scale at 25 degrees C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 MOhm (Voltage Mode) \/ 250 Ohm (Current Mode Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-Channel and System-to-Channel Galvanic Isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOvervoltage Safeguard\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProtects Up to 150 Vrms Against Electrical Surges\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Supplied Directly via the Chassis Backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e170 mm x 105 mm x 32 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +60 degrees C Standard Industrial Range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminates Ground Loop Inaccuracies:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eComplete channel-to-channel and system-to-channel galvanic isolation physically blocks stray ground currents. This electrical separation prevents signal corruption on adjacent channels when field instruments operate at different ground potentials.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplifies Enclosure Thermal Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe low-power internal hardware architecture reduces heat generation inside high-density I\/O panels. The compact 170 mm x 105 mm x 32 mm body allows control system engineers to mount multiple DAI 01 cards side-by-side without installing auxiliary cabinet cooling fans.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRepels Heavy Electromagnetic Noise:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-performance internal filters suppress high-frequency electromagnetic interference (EMI) originating from nearby heavy motors, variable speed drives, and switching relays, maintaining analog signal integrity down to 0.1 percent accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShields Loops from Severe Overvoltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in protection circuitry tolerates accidental overvoltage and overcurrent faults up to 150 Vrms. This robust buffer prevents field wiring mistakes or inductive lightning surges from damaging the central Freelance DCS processor bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I shift a channel on the DAI 01 from a 4-20 mA current loop to a 0-10 V voltage input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou configure the signal type per channel using the standard ABB Freelance DCS engineering software suite. The software programs the internal resolution between 12-bit and 16-bit and switches the input impedance networks electronically; you do not need to install physical hardware jumpers on the card.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the DAI 01 backplane connection support hot-swapping under live power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlways verify the specific revision guidelines of your ABB Freelance rack chassis before replacing components. While the module architecture protects the system bus during insertion, powering down the local I\/O rack strip before card replacement prevents unexpected signal trips in active, downstream control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does the reported module weight vary so significantly in the documentation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe baseline printed circuit board assembly weighs approximately 0.12 kg. The final weight increases toward the upper threshold of 1.69 kg only when you order the module complete with heavy-duty ruggedized field housings, external terminal blocks, or specialized mechanical mounting frames.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":42870824632410,"sku":"DAI 01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/112._065b7ce4-c4c9-4c5c-81de-cad6a63ca8b5.jpg?v=1771896409","url":"https:\/\/www.spareoil.com\/products\/dai-01-abb-freelance-dcs-analog-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}