{"product_id":"deltav-ve5132-power-supply-redundancy-w-conformal-coating","title":"DeltaV VE5132 Power Supply Redundancy w\/ Conformal Coating","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson VE5132\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-capacity Power Supply Redundancy Module designed for both DeltaV™ and Ovation™ Distributed Control Systems (DCS). This module manages up to 40 Amps of continuous current, providing a stabilized 24VDC output to controllers, I\/O modules, and critical field instrumentation. By facilitating dual DC input paths, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVE5132\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeliminates single points of failure in the power distribution layer. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal equipment, featuring factory-applied conformal coating to ensure long-term stability in corrosive or high-humidity industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVE5132\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeltaV™ Bulk Power \/ Ovation™ DCS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 Amps (Continuous)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Regulated (Typical 12-28V Range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual Redundant DC Input Paths\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≥90% at Full Load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOver-voltage, Over-current, Short-circuit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConformal Coating (Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 °C to +60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Rack \/ Carrier System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 lbs (0.9 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Amperage Redundancy\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVE5132\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehandles a massive 40-amp load, allowing a single redundancy module to support large-scale I\/O density. The dual-path architecture ensures that if one primary bulk power source fails, the module transitions the load seamlessly to the secondary source without dropping voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Thermal Efficiency\u003c\/strong\u003e: Operating at ≥90% efficiency, the module minimizes internal heat dissipation. This reduced thermal footprint extends the life of adjacent I\/O cards within the cabinet and lowers the cooling requirements for the overall control room.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3-Rated Environmental Defense\u003c\/strong\u003e: Emerson applies a conformal coating to all internal circuit boards. This protective layer guards against conductive dust, moisture, and chemical contaminants, meeting the rigorous demands of offshore oil platforms and chemical refineries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Fault Diagnostics\u003c\/strong\u003e: The module incorporates active monitoring to detect input voltage irregularities or internal circuit failures. These diagnostics integrate directly into the DCS software, providing operators with immediate alerts before a power loss affects the process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Footprint\u003c\/strong\u003e: Despite its 40-amp capacity, the modular design fits into standard Ovation and DeltaV rack systems. This space-efficient engineering allows for redundant power configurations even in cabinets with limited DIN rail or carrier space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the VE5132 and standard power modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVE5132\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically a\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eredundancy module\u003c\/em\u003e. It does not necessarily generate power itself but instead manages the inputs from two separate bulk power supplies to ensure the system always has a \"clean\" 24VDC output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. In a redundant system configuration, you can replace a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVE5132\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule while the system remains powered. The secondary redundancy module or the alternate path maintains the 24VDC rail to prevent a system shutdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 40 Amp rating for the whole rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 40 Amp rating refers to the maximum continuous current the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVE5132\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan safely pass and regulate. You must ensure that the total current draw of your controllers and I\/O modules does not exceed this limit for a single redundancy group.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43131384987738,"sku":"VE5132","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/338._24534d23-0afd-4ae5-a4a7-fe77f07eaef5.jpg?v=1774512183","url":"https:\/\/www.spareoil.com\/products\/deltav-ve5132-power-supply-redundancy-w-conformal-coating","provider":"SpareOil Automation","version":"1.0","type":"link"}