{"product_id":"desktop-operation-keyboard-yokogawa-aip830-101-eim-centum-vp","title":"Desktop Operation Keyboard | Yokogawa AIP830-101\/EIM CENTUM VP","description":"\u003ch2\u003eYokogawa AIP830-101\/EIM Operation Keyboard\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa AIP830-101\/EIM\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAIP830\u003c\/strong\u003e Operation Keyboard, operates as a dedicated hardware component for human-machine operator input and alarm execution within CENTUM VP Human Interface Stations (HIS). Configured with dual USB interfaces, this console unit transmits real-time tactile keypresses, mode selections, and audio alarm responses directly to the desktop workstation terminal.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode \/ Suffix Segment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model: AIP830\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation Keyboard\u003c\/td\u003e\n\u003ctd\u003eUSB-based operator interface panel for CENTUM VP HIS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix: -1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMode Switch\u003c\/td\u003e\n\u003ctd\u003eIntegrated mode selection switch for station privilege control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix: 0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfirmation Key\u003c\/td\u003e\n\u003ctd\u003eOperation confirmation key Type A structure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix: 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed Code\u003c\/td\u003e\n\u003ctd\u003eStandard fixed hardware revision indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOption: \/EIM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual Specification\u003c\/td\u003e\n\u003ctd\u003eSupplied with English Instruction Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAIP830-101\/EIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndonesia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 kg (without VESA bracket)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 mm x 285 mm x 52 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 40 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V DC +\/-5% (1 A maximum, bus-powered via USB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeyboard Layout\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlat industrial console with 64 customizable function keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAudio System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated USB speaker and audible alarm buzzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHost Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual USB A-type connectors (USB 2.0 input, USB 1.1 audio)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Finish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlack (Munsell No. N1.5 equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDesktop placement or VESA mount bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20% to 80% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa CENTUM VP desktop HIS workstations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1 Class I standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eWhile the AIP830-101\/EIM functions at the operator supervisory layer, its 64 user-definable keys directly manipulate real-time DCS field loops across the backplane bus. Keypress commands triggered on the console pass through the CENTUM VP HIS graphic engine to adjust output targets, trip safety overrides, or acknowledge critical alarm vectors. Independent galvanic isolation at the field I\/O subsystem level prevents ground loops and electrical transients on field-side 4-20 mA HART loop channels from propagating back to the workstation console, maintaining signal integrity and operator terminal stability during high-density field switching operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Why does the AIP830-101\/EIM require two separate USB interface cables connected to the host PC?\u003c\/p\u003e\n\u003cp\u003eA: One USB connector supplies 5 V DC power and transmits USB 2.0 keypress data signals, while the second USB connector handles USB 1.1 digital audio streaming for the onboard speaker and alarm buzzer.\u003c\/p\u003e\n\u003cp\u003eQ: Can the keyboard be installed on a standard monitor arm instead of flat desktop placement?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the unit supports VESA mounting, provided the mounting arm or bracket is rated to support a mechanical static load of at least 10 kg.\u003c\/p\u003e\n\u003cp\u003eQ: How does the mode selection switch affect operator command execution?\u003c\/p\u003e\n\u003cp\u003eA: The physical mode selection switch restricts command entry rights directly at the console level, preventing unauthorized loop tuning, setpoint modification, or emergency override execution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eWhen installing and wiring the Yokogawa AIP830-101\/EIM operation keyboard at a control room operator console, follow these procedures:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003ePosition the keyboard on a clean, flat desktop surface or secure it to a VESA-compliant arm using the recommended mounting hardware.\u003c\/li\u003e\n\u003cli\u003eConnect both USB A-type cables directly to root USB hub ports on the host CENTUM VP HIS workstation to ensure adequate 5 V DC power distribution (up to 1 A).\u003c\/li\u003e\n\u003cli\u003eRoute the USB cables away from high-voltage power leads, motor drive wiring, and AC distribution panels to prevent electromagnetic interference from affecting keyboard communication.\u003c\/li\u003e\n\u003cli\u003eVerify that host system device drivers load correctly and test the 64 function keys and mode switch using the CENTUM VP keyboard test utility.\u003c\/li\u003e\n\u003cli\u003eKeep liquid containers away from the flat keyboard faceplate to avoid fluid ingress into internal switch contacts and speaker grilles.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43855776251994,"sku":null,"price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/793_3afab4a1-18cb-4ba7-982b-38328efd585b.jpg?v=1786935303","url":"https:\/\/www.spareoil.com\/products\/desktop-operation-keyboard-yokogawa-aip830-101-eim-centum-vp","provider":"SpareOil Automation","version":"1.0","type":"link"}