{"product_id":"devicenet-configuration-terminal-193-dnct-allen-bradley","title":"DeviceNet Configuration Terminal | 193-DNCT Allen Bradley","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen Bradley 193-DNCT serves as a portable, handheld configuration terminal engineered specifically for commissioning, diagnosing, and programming devices on active DeviceNet networks. This industrial tool interfaces directly with Allen Bradley E3 and E3 Plus overload relays, as well as 280, 281, 283, and 284 ArmorStart distributed motor controllers. By removing the need for a dedicated laptop or complex software routing on the factory floor, the unit grants engineers immediate operational access to network nodes. We offer this item as a 100% brand-new, factory-original unit in its original packaging, backed by fast global logistics.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE3, E3 Plus, ArmorStart Accessories\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e193-DNCT (BZ1 Package Variant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original Packaging\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Format\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHandheld Portable Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDisplay Device\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBacklit LCD Screen with Menu Navigation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTactile Keypad for Parameter Entry\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeviceNet Network Protocol\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e193-EC, 193-EDN, ArmorStart 280\/281\/283\/284 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11 to 25 VDC (Draws power directly from DeviceNet trunk)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +50 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAmbient Humidity Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 percent to 95 percent non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Device Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompliance Approvals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL, CSA, CE Compliant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminates Local PC Dependency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe handheld terminal establishes a direct connection to any DeviceNet drop point, allowing field engineers to edit parameters, assign node addresses, and adjust baud rates without carrying a laptop or downloading specific electronic data sheets (EDS files).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccelerates Fault Interventions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated diagnostic screens pull live status words directly from connected motor starter coils and protection relays. The keypad layout speeds up troubleshooting by displaying real-time fault codes for overloads, phase loss, underloads, and ground faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplifies Power Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal regulator harvests operational power directly from the DeviceNet bus cable lines (11-25 VDC). This eliminates the dependency on standard disposable batteries or external AC wall adapters during long maintenance cycles inside deep enclosure cells.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlines Multi-Device Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe intuitive menu-driven LCD layout standardizes how plant engineers modify protection thresholds on complex distributed drive nodes. This layout uniformity minimizes manual entry typos during critical machine rebuilding phases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 193-DNCT to configure newer EtherNet\/IP or ControlNet devices?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This specific field tool contains transceiver hardware dedicated solely to the DeviceNet protocol and physical bus layers. It will not communicate with modern EtherNet\/IP, Profibus, or standard Modbus TCP automation architectures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit require an external power supply or charging adapter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The terminal powers up automatically as soon as you plug it into a live DeviceNet network cable node. It relies entirely on the nominal 24V DC auxiliary power carried by standard DeviceNet network trunks (functioning down to 11V DC).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific Allen Bradley starter components work with this configuration terminal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 193-DNCT integrates natively with E3 and E3 Plus solid-state overload relays (such as the 193-EC and 193-EDN modules). It also supports all standard multi-drive configurations within the ArmorStart 280, 281, 283, and 284 distributed motor starter families.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":43404027265114,"sku":"193-DNCT","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/107_ca2c66a2-0ea8-4ec5-9d8f-b6e672a4e018.jpg?v=1779412806","url":"https:\/\/www.spareoil.com\/products\/devicenet-configuration-terminal-193-dnct-allen-bradley","provider":"SpareOil Automation","version":"1.0","type":"link"}