{"product_id":"ds200dtbag1aaa-ge-mark-v-termination-module-new-stock","title":"DS200DTBAG1AAA GE Mark V Termination Module | New Stock","description":"\u003ch1\u003eGE DS200DTBAG1AAA Mark V Speedtronic Turbine Control System\u003c\/h1\u003e\n\u003cp\u003eConfigured for discrete signal routing and conditioning in GE Mark V Speedtronic Turbine Control System, the \u003cstrong\u003eGE DS200DTBAG1AAA\u003c\/strong\u003e (\u003cstrong\u003eDS200DTBA\u003c\/strong\u003e) Digital Contact Input Termination Board provides direct physical and electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDS200\u003c\/strong\u003e : Standard full-size drive board design platform for the Mark V architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDTBA\u003c\/strong\u003e : Digital Contact Input Termination Board functional layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG1\u003c\/strong\u003e : Group 1 assembly variation mapping specific connector configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e : Functional engineering release version.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e : Manufacturing artwork revision state.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e : Component bill of materials revision pattern.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eDS200DTBAG1AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e11 x 8 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003ePowered via system backplane interface links\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eTotal Field Connections\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e190 termination points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eBlock Allocation\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eTwo distinct terminal blocks containing 95 points each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eSignal Classification\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eDiscrete \/ Digital dry contact inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eJ12, JQR, JQS\/T, and JY ribbon headers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFirmware Flash Compatibility and Deterministic Bus Communication\u003c\/h3\u003e\n\u003cp\u003eThe board transmits processed discrete state data to the primary control processors through standard multi-pin ribbon cables. To maintain proper diagnostic execution across all 190 termination points, the board hardware matches the hardware scaling properties defined in the core system firmware flash compatibility profile. System software registers monitor input signals deterministically via the J12 and JQR header pathways. Proper data framing prevents bus cycle delays, ensuring that field changes update within the targeted scan rate of the internal controller backplane.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can single channels or entire terminal blocks be hot-swapped while the Mark V rack is actively controlling the turbine?\u003c\/p\u003e\n\u003cp\u003eA: No. Disconnecting the J-headers or loose contact field lines while the rack is powered can cause communication interruptions on the control bus, leading to unintended system trips or false diagnostic fault generation.\u003c\/p\u003e\n\u003cp\u003eQ: How is field contact excitation power derived for the discrete input circuits connected to this board?\u003c\/p\u003e\n\u003cp\u003eA: The board routes regulated distribution voltage from the internal Mark V power core through its ribbon connections, establishing the necessary potential for wet-contact or dry-contact field verification loops.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the 11 x 8 inch printed circuit board directly to the designated metal chassis supports inside the Mark V control enclosure.\u003c\/li\u003e\n\u003cli\u003eStrip field conductors exactly to the dimensions specified by the terminal block manufacturer to prevent open circuits or shorting between adjacent pins.\u003c\/li\u003e\n\u003cli\u003eGroup and secure the heavy field wiring bundles with wire ties to reduce mechanical strain on the board assembly terminal blocks.\u003c\/li\u003e\n\u003cli\u003eRoute ribbon cables from headers J12, JQR, JQS\/T, and JY cleanly away from power distribution lines to prevent induced noise on transmission pathways.\u003c\/li\u003e\n\u003cli\u003eGround the system enclosures in accordance with document GEH-6353 to ensure the physical isolation barriers function within noise suppression limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42870896525402,"sku":"DS200DTBAG1AAA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/78_d320fe25-a5e1-49c6-b29a-0d43f9aa2099.jpg?v=1770948037","url":"https:\/\/www.spareoil.com\/products\/ds200dtbag1aaa-ge-mark-v-termination-module-new-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}