{"product_id":"ds200tbqcg1a-ge-mark-v-analog-input-milliamp-i-o-termination-module","title":"DS200TBQCG1A GE Mark V Analog Input Milliamp I\/O Termination Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE DS200TBQCG1A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200TBQC\u003c\/strong\u003e Analog Input Milliamp I\/O Termination Module, operates as a dedicated hardware component for milliamp signal termination and position feedback routing within Speedtronic Mark V Turbine Control System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TBQCG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard PCB footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark V terminal board profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane driven\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eTBQC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRST Analog Termination Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Blocks\u003c\/td\u003e\n\u003ctd\u003e2 blocks (TB1, TB2; 83 terminals per block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Capacity\u003c\/td\u003e\n\u003ctd\u003e166 signal wire connections total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Jumpers\u003c\/td\u003e\n\u003ctd\u003e15 jumpers (labeled BJ1 through BJ17)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Connectors\u003c\/td\u003e\n\u003ctd\u003e3 40-pin connectors, 3 34-pin connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDedicated Signal Connectors\u003c\/td\u003e\n\u003ctd\u003eJBR (TCQA Board I\/O), JFR (TCQA Board LVDT\/R Position)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnused\/Vestigial Connectors\u003c\/td\u003e\n\u003ctd\u003eJBS\/T, JFS\/T, TEST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Coating\u003c\/td\u003e\n\u003ctd\u003eNormal Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Revision\u003c\/td\u003e\n\u003ctd\u003eGroup 1, Revision A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe DS200TBQCG1A expands system I\/O density scaling across 166 individual terminal points split between blocks TB1 and TB2, interfacing high-density field milliamp inputs directly to the RST control cores. Discrete signals for position feedback, such as LVDT\/R inputs, and general I\/O streams are multiplexed through 40-pin and 34-pin ribbon headers (including JBR and JFR) to the TCQA processor board. Configured via 15 hardware jumpers (BJ1 to BJ17), signal lines maintain high backplane bus communication velocity across deterministic Mark V internal networks while preserving firmware flash compatibility.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What function do the JBR and JFR ribbon connectors serve on the DS200TBQCG1A?\u003c\/p\u003e\n\u003cp\u003eA: Connector JBR routes input and output signals to the TCQA board, while connector JFR routes Linear Variable Differential Transformer (LVDT\/R) position feedback signals directly to the TCQA processor.\u003c\/p\u003e\n\u003cp\u003eQ: Are the JBS\/T, JFS\/T, and TEST connectors required for standard module operation?\u003c\/p\u003e\n\u003cp\u003eA: No, connectors JBS\/T, JFS\/T, and TEST serve as vestigial connectors that remain unused during standard operation of the DS200TBQCG1A module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize all main supply lines and field power sources feeding the Mark V cabinet prior to installing or servicing the board.\u003c\/li\u003e\n\u003cli\u003eVerify zero-energy state across all terminal points on blocks TB1 and TB2 using a calibrated multi-meter.\u003c\/li\u003e\n\u003cli\u003eWear a grounded anti-static wrist strap throughout board handling to protect semiconductor components from electrostatic discharge (ESD).\u003c\/li\u003e\n\u003cli\u003eTag each signal wire with its corresponding terminal block ID (TB1 or TB2) and numerical terminal ID (1 to 83) prior to disconnecting existing wiring.\u003c\/li\u003e\n\u003cli\u003eSecure field wiring into the 166 screw terminals, verify jumper positions BJ1 through BJ17 against system drawings, and fully seat all multi-pin ribbon cables before restoring power.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43913258598490,"sku":"DS200TBQCG1A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/DS200TBQCG1ABB.jpg?v=1787713439","url":"https:\/\/www.spareoil.com\/products\/ds200tbqcg1a-ge-mark-v-analog-input-milliamp-i-o-termination-module","provider":"SpareOil Automation","version":"1.0","type":"link"}