{"product_id":"ds200tccbg3b-ge-mark-v-extended-analog-i-o-board","title":"DS200TCCBG3B GE Mark V Extended Analog I\/O Board","description":"\u003cp\u003eConfigured for analog signal processing and扩展 I\/O routing in GE Mark V turbine control systems, the \u003cstrong\u003eGE DS200TCCBG3B\u003c\/strong\u003e (\u003cstrong\u003eDS200TCCB\u003c\/strong\u003e Extend Analog I\/O Card) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TCCBG3B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eTCCB (TC2000 Analog Board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Revision\u003c\/td\u003e\n\u003ctd\u003eGroup 3, Revision B (G3B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Coating\u003c\/td\u003e\n\u003ctd\u003eNormal Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e1 x 80196 Microprocessor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eMultiple PROM modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003e1 x Green Status LED (side-viewable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003e2 x 50-pin connectors (JCC, JDD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Selection\u003c\/td\u003e\n\u003ctd\u003eHardware jumpers for generator and bus voltage selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard GE Mark V Board Size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard GE Mark V Board Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane bus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCCBG3B utilizes high-density backplane connection interfaces via its 50-pin JCC and JDD connectors to preserve backplane bus communication velocity across the Mark V architecture. Driven by an onboard 80196 microprocessor and dedicated PROM firmware, the card scales I\/O density by expanding processing paths for auxiliary analog inputs and outputs. Integrated hardware jumpers enable precise physical configuration of generator and bus voltage scale factors directly on the board, eliminating latency in high-speed turbine control loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What operational status does the onboard green LED indicate?\u003c\/p\u003e\n\u003cp\u003eA: The green LED indicates active power delivery and module execution. If the LED is unlit during system operation, it signifies a loss of input power or a processor halt condition.\u003c\/p\u003e\n\u003cp\u003eQ: What functions do the JCC and JDD connectors serve on the DS200TCCBG3B?\u003c\/p\u003e\n\u003cp\u003eA: The JCC and JDD 50-pin header connectors route high-density analog signals and bus communications between the TCCB card and the primary Mark V control rack.\u003c\/p\u003e\n\u003cp\u003eQ: How are generator and bus voltage measurement ranges configured on this module?\u003c\/p\u003e\n\u003cp\u003eA: Generator and bus voltage levels are selected mechanically via a series of onboard manually-moveable hardware jumpers prior to system commissioning.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower down the Mark V control cabinet and follow lock-out\/tag-out (LOTO) procedures before removing or inserting the PCB.\u003c\/li\u003e\n\u003cli\u003eWear a grounded ESD wrist strap connected to the cabinet frame to protect the onboard 80196 microprocessor and PROM modules from static discharge.\u003c\/li\u003e\n\u003cli\u003eEnsure proper alignment of the 50-pin ribbon cable connectors (JCC and JDD) to prevent bent header pins during installation.\u003c\/li\u003e\n\u003cli\u003eVerify jumper positions against system electrical schematics prior to applying backplane power to ensure correct voltage scaling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43918572683354,"sku":"DS200TCCBG3B","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/DS200TCCBG3B1.png?v=1787813567","url":"https:\/\/www.spareoil.com\/products\/ds200tccbg3b-ge-mark-v-extended-analog-i-o-board","provider":"SpareOil Automation","version":"1.0","type":"link"}