{"product_id":"emerson-5x00226g04-analog-output-module-new-original-stock","title":"Emerson 5X00226G04 Analog Output Module | New \u0026 Original Stock","description":"\u003ch2\u003eEmerson 5X00226G04 Ovation Series\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson 5X00226G04\u003c\/strong\u003e serves as the primary \u003cstrong\u003e5X00226G04\u003c\/strong\u003e Analog Output Module utilized to execute precision control of actuators across Ovation Series platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5X00226G04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e150 mm x 81 mm x 52 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eRack powered via backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 analog outputs (4-20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit (0.0015% full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.05% over 12 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5 ms (0-100% full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1000 VDC channel-to-channel, 2500 VDC channel-to-backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation\u003c\/h3\u003e\n\u003cp\u003eThe electrical architecture incorporates a 4-20 mA HART loop protocol enabling HART 7.0 pass-through communication for remote valve positioner calibration. Galvanic protection is achieved through 1000 VDC channel-to-channel isolation paired with 2500 VDC channel-to-backplane isolation to suppress transient signals. The 16-bit digital-to-analog converter drives field loops with an update response time of less than 5 ms, mitigating signal drift across critical modulation valves.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the hot-standby redundancy loop configured for this hardware?\u003c\/p\u003e\n\u003cp\u003eA: Redundant operations require pairing the 5X00226G04 module with a 5X00227G04 base unit in a 1:1 hardware configuration. The Ovation backplane manages tracking variables to execute a bumpless transfer if a fault is detected on the active module.\u003c\/p\u003e\n\u003cp\u003eQ: What are the continuous and peak current output thresholds for the channels?\u003c\/p\u003e\n\u003cp\u003eA: Each channel delivers a continuous current output of 0-20 mA. The loop circuitry is capable of sustaining a peak current of 30 mA for a maximum duration of 10 seconds under high-demand actuator states.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module log and display internal loop faults or hardware failures?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module features built-in diagnostics that continually scan channel integrity and internal component health, reporting faults directly to the controller while driving faceplate LED status indicators.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Thermal Maintenance:\u003c\/strong\u003e When installing modules in dense 1U slot clusters, provide an unhindered vertical exhaust path. Verify that convective airflow maintains the localized internal rack temperature below +60 deg C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Specifications:\u003c\/strong\u003e Terminate the analog cable outer shields at the designated single-point cabinet ground busbar. Do not ground shields at the field instrument side to prevent low-frequency ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Conduits and Separation:\u003c\/strong\u003e Run all 4-20 mA analog output conductors in dedicated, grounded metallic trays separate from high-voltage AC or inductive motor control circuits to block electromagnetic noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43479599677530,"sku":"5X00226G04","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/446._f28f8dec-4d6a-4dfe-a135-53a8d97e6a50.jpg?v=1781163083","url":"https:\/\/www.spareoil.com\/products\/emerson-5x00226g04-analog-output-module-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}