{"product_id":"emerson-ovation-1c31116g03-series-datasheet-technical-manual","title":"Emerson Ovation 1C31116G03 Series Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eEmerson 1C31116G03 Ovation Series\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson 1C31116G03\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1C31116G03\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for converting digital commands from Ovation controllers into discrete output signals within Ovation DCS networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1C31116G03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eThailand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 x 9.7 x 12.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (rack powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 digital output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Voltage Range\u003c\/td\u003e\n\u003ctd\u003e24 VDC or 48 VDC (jumper selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eIsolated, single-ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e2500 VDC channel-to-backplane isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eBuilt-in fault detection, LED indicators per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eShort-circuit and overload protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Tolerance\u003c\/td\u003e\n\u003ctd\u003e5-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, IEC 61131-2 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation\u003c\/h3\u003e\n\u003cp\u003eThe electrical topology incorporates channel-to-channel isolation networks designed to suppress high-voltage common-mode transients from disrupting the inner processing layer. Dedicated circuit paths route output current loops through individual semiconductor switches, regulating inductive and resistive field loads up to 0.5 A per node. Integral diagnostic arrays track operational status indicators across the interface terminal plane, maintaining constant open-circuit and thermal overload fault evaluation during high-frequency execution cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the physical signal voltage layer configured for 24 VDC or 48 VDC operational baselines?\u003c\/p\u003e\n\u003cp\u003eA: Selection between the 24 VDC and 48 VDC field output voltage thresholds requires manual position adjustments of the structural jumpers located directly on the module circuit board prior to rack mounting.\u003c\/p\u003e\n\u003cp\u003eQ: What mitigation actions does the hardware execute during an external dead short-circuit event?\u003c\/p\u003e\n\u003cp\u003eA: Onboard protection circuitry isolates the affected path via electronic current-limiting boundaries, resetting automatically once the field wiring short-circuit condition is rectified.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eLock the module alignment rails within the designated Ovation chassis slot, engaging the low-impedance multi-pin backplane connector to complete the internal power circuit. Separate all field discrete output cabling runs from parallel high-voltage AC distribution bus ducts inside the cable trays to prevent inductive interference. Connect all control circuit common shield wires to the plant master instrumentation earth bus at a single connection node. Maintain unobstructed space clearances above and below the rack perimeter to ensure steady vertical air flow currents for continuous thermal dissipation.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43484125233242,"sku":"1C31116G03","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/454._c0997385-2fe6-4211-b9fd-a791ce691704.jpg?v=1781227743","url":"https:\/\/www.spareoil.com\/products\/emerson-ovation-1c31116g03-series-datasheet-technical-manual","provider":"SpareOil Automation","version":"1.0","type":"link"}