{"product_id":"emerson-rx3i-ic694dnm200-devicenet-communication-card","title":"Emerson RX3i IC694DNM200 DeviceNet Communication Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc Emerson IC694DNM200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary DeviceNet communication gateway for the PACSystems RX3i and legacy Series 90-30 platforms. This module functions as a robust DeviceNet Master, coordinating bi-directional data exchange between the central PLC and up to 63 downstream slave devices. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, ensuring factory-sealed reliability for critical infrastructure in automotive assembly, material handling, and packaging sectors. It effectively bridges the CPU with a vast array of CAN-based sensors, actuators, and motor starters.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IC694DNM200 provides high-density I\/O mapping and flexible baud rate selection for optimized network performance.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Role\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeviceNet Master (Scanner)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSlave Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 63 Slave Nodes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Rates\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125k, 250k, or 500k baud (Selectable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e255 Bytes Input \/ 255 Bytes Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRX3i Universal Backplane \u0026amp; Series 90-30 Backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e450mA @ 5VDC (from backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExternal Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24VDC +\/- 4% (Network Power)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eService Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOne (1) RS-232 Service Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeviceNet (ODVA Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Node Density Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA single IC694DNM200 module orchestrates communication for 63 slave devices. This high-density capacity reduces the required number of PLC modules, saving valuable cabinet space and lowering total system hardware costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLegacy and Modern Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module bridges the gap between older Series 90-30 systems and modern PACSystems RX3i controllers. This makes it an ideal solution for facility upgrades where existing DeviceNet cabling and slave devices remain in place.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Diagnostic Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuring power-up, the module automatically executes diagnostic address detection. Integrated LEDs on the front panel provide real-time status for the module and the network, allowing technicians to isolate cabling faults or node failures without connecting a laptop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Data Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupport for 500kbps baud rates enables the fast response times necessary for high-speed packaging and sorting applications. The module manages 255 bytes of I\/O data per scan, ensuring the CPU receives a complete image of the field network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the IC694DNM200 require external power for the network?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the module draws 5VDC from the PLC backplane for its internal logic, the DeviceNet network itself requires a separate 24VDC power supply. This external power drives the communication transceivers in each connected slave node.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module to replace a discontinued Series 90-30 DeviceNet card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC694DNM200 maintains full compatibility with Series 90-30 backplanes, provided you use an RX3i CPU (Version 3.5 or later) or a compatible Series 90-30 processor. It serves as a direct functional upgrade.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the baud rate for the network?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou set the communication rates (125k, 250k, or 500k) via the GE Logic Developer (PME) software. The module then automatically negotiates with the nodes during the network scan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs redundancy supported with the IC694DNM200?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This specific module does not support hot-standby redundancy. It is designed for standard, high-reliability DeviceNet master applications where a single master controls the designated node group.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43321582420058,"sku":"IC694DNM200","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/536..jpg?v=1778059215","url":"https:\/\/www.spareoil.com\/products\/emerson-rx3i-ic694dnm200-devicenet-communication-card","provider":"SpareOil Automation","version":"1.0","type":"link"}