{"product_id":"esb-bus-node-unit-yokogawa-anb10d-426-cu2n-ndel","title":"ESB Bus Node Unit Yokogawa ANB10D-426\/CU2N\/NDEL","description":"\u003ch2\u003eYOKOGAWA ANB10D-426\/CU2N\/NDEL ESB Bus Node Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for Specific Technical Task in System\/Network Name, the \u003cstrong\u003eYOKOGAWA ANB10D-426\/CU2N\/NDEL\u003c\/strong\u003e (\u003cstrong\u003eANB10D\u003c\/strong\u003e ESB Bus Node Unit) provides direct physical\/electrical execution. The hardware establishes deterministic communication links between high-density input\/output sub-modules and the central Field Control Unit over a synchronized bus architecture. Engineered with a dual-redundant power topology, this rack-mounted node facilitates real-time data serialization and multi-channel hardware distribution across the local network backplane.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANB10D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eNode Unit for Dual-Resistant ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSuffix\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSuffix\u003c\/td\u003e\n\u003ctd\u003e220 V AC to 240 V AC power input rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSuffix\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 conformal coating, extended temperature (-20 to 70 deg C), non-explosion proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\/CU2N\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOption\u003c\/td\u003e\n\u003ctd\u003eConnector Unit for ESB Bus (2 pieces, Part No. S9562FA, non-terminated variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\/NDEL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOption\u003c\/td\u003e\n\u003ctd\u003eEmbedded Software License for Node Expansion functionality\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB10D-426\/CU2N\/NDEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg (Shipping weight) \/ 10 kg (Gross operational assembly weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 19-inch rack-mount footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e230 VA (Apparent power), 120 W (Active power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003eDual-redundant 220 to 240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Topology\u003c\/td\u003e\n\u003ctd\u003eDual-redundant synchronous ESB bus lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Capacity\u003c\/td\u003e\n\u003ctd\u003eMaximum 8 FIO modules per individual node structure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Capacity\u003c\/td\u003e\n\u003ctd\u003eScalable up to 13 units per AFV30\/AFV40 Field Control Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Code\u003c\/td\u003e\n\u003ctd\u003eISA G3 class conformal coating for atmospheric protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDistributed Control System Technical Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe unit leverages direct backplane bus communication velocity parameters to process parallel data packets from connected input\/output cards without processing latency. Channel-to-channel isolation matrices insulate the internal digital translation pathways from external loop spikes, keeping the system logic common independent of field terminal noise. The integrated \/CU2N connector block serves intermediate loop connection configurations, enabling continuous signal pass-through along the dual-redundant synchronous bus without terminating the physical transmission line network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the internal power system respond if one of the dual-redundant 220 V AC utility lines suffers a total voltage collapse?\u003c\/p\u003e\n\u003cp\u003eA: The internal power architecture initiates an automatic failover sequence executed within 2 microseconds. The parallel online supply module assumes the full current load without causing interruption to the active backplane data processing or dropping the ESB bus synchronization.\u003c\/p\u003e\n\u003cp\u003eQ: Can the \/CU2N connector unit assembly be placed at the physical end of the ESB bus line chain?\u003c\/p\u003e\n\u003cp\u003eA: No. The \/CU2N is a non-terminated connector design intended strictly for intermediate node pass-through configurations. Terminal positions at the end of the bus chain require the installation of a dedicated terminated type block (CU2T) to avoid signal reflection errors.\u003c\/p\u003e\n\u003cp\u003eQ: Is this specific model variation rated for mounting within Class 1 Division 2 hazardous areas?\u003c\/p\u003e\n\u003cp\u003eA: No. The -426 suffix designation denotes a non-explosion protected hardware profile. The module must be installed in a non-hazardous control room environment or within an appropriately purged and pressurized industrial enclosure.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Integration:\u003c\/strong\u003e Position the chassis into a standard 19-inch equipment rack frame. Secure the unit through the faceplate mounting slots utilizing M5 pan-head screws, verifying that the structure is level and free of mechanical stress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Termination:\u003c\/strong\u003e Fit the two provided S9562FA connector units from the \/CU2N kit firmly onto the corresponding rear ESB bus ports. Ensure the locking tabs snap home to prevent high-frequency data corruption from loose pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Mitigation:\u003c\/strong\u003e Maintain clear, unobstructed clearance above and below the rack chassis. In operating environments tracking near the upper +70 deg C limit, ensure active exhaust fan systems maintain continuous volumetric airflow across the internal components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Grounding:\u003c\/strong\u003e Connect a dedicated low-impedance copper conductor from the ground stud on the rear panel directly to the central Instrument Earth bus bar. Avoid daisy-chaining ground wires to preserve high noise-rejection ratios across the node backplane.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43698471600218,"sku":"ANB10D-426\/CU2N\/NDEL","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/652..jpg?v=1784684264","url":"https:\/\/www.spareoil.com\/products\/esb-bus-node-unit-yokogawa-anb10d-426-cu2n-ndel","provider":"SpareOil Automation","version":"1.0","type":"link"}