{"product_id":"f2-do-16-02-hima-sil-3-safety-remote-i-o-module-new","title":"F2 DO 16 02 HIMA SIL 3 Safety Remote I\/O Module New","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHIMA F2DO1602\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(F2 DO 16 02) is a high-density, safety-related remote I\/O module designed for the HIMatrix platform. This module serves as a critical interface in Distributed Safety Systems, controlling actuators such as solenoids, relays, and pilot lamps. With 16 digital outputs, the F2DO1602 provides the deterministic response times required for Emergency Shutdown (ESD) and Burner Management Systems (BMS). We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your facility maintains its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 3 (IEC 61508\/61511)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrity with genuine German-engineered hardware.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe F2DO1602 combines high channel density with robust electrical isolation:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eF2DO1602 (F2 DO 16 02)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Digital Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelay outputs, potential-free contacts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLoad Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 2 A per channel (Resistive)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integrity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL 3 \/ Category 4 \/ PLe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafeEthernet, Modbus TCP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWire-break and Short-circuit monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Area\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX \/ Ex Zone 2 Compliant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 10 ms typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–20°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe F2DO1602 provides several technical benefits for safety-critical automation:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Integrity SafeEthernet:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes SafeEthernet protocols to transmit safety-related data over standard Ethernet infrastructure. This allows for the decentralization of I\/O without sacrificing the SIL 3 safety rating, significantly reducing field wiring costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Fault Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach of the 16 channels features active monitoring for external wiring faults. The module identifies short circuits and wire breaks instantly, triggering LED indicators and notifying the central safety controller to prevent \"fail-to-danger\" scenarios.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Zone 2 Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module carries Ex Zone 2 certification, allowing for installation in hazardous areas closer to the field devices. This proximity reduces signal degradation and simplifies the overall architecture of the Safety Instrumented System (SIS).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay-Based Potential-Free Contacts:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16 potential-free relay outputs provide electrical isolation between the 24 VDC control logic and the field load. This protects the internal circuitry from voltage spikes and ground loops common in industrial power systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the F2DO1602 and the F2DO801?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile both belong to the HIMatrix series, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF2DO1602\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers 16 digital outputs at 24 VDC, doubling the channel density of the F2DO801. The F2DO801 is specifically known for handling higher AC\/DC voltages (up to 250V) on its 8 relay channels, whereas the F2DO1602 is optimized for 24 VDC safety loads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich programming tool should I use for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe F2DO1602 is fully compatible with HIMA’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSILworX\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration software and the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eELOP II Factory\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprogramming tool. This ensures seamless integration into existing HIMA projects and supports all IEC 61131-3 compliant languages.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe HIMatrix remote I\/O architecture supports modular replacement. However, because this is a SIL 3 safety component, you must ensure that the safety function is appropriately bypassed or that the system is in a safe state during replacement to comply with your facility's safety manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of potential-free contacts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePotential-free contacts allow the module to switch external circuits that have their own power source. This prevents the mixing of power supplies and provides a high level of galvanic isolation, which is vital for preventing common-cause failures in safety loops.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43372443795546,"sku":"F2DO1602","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/199._43394122-4426-413f-a92d-014cff7e6aa0.jpg?v=1778739024","url":"https:\/\/www.spareoil.com\/products\/f2-do-16-02-hima-sil-3-safety-remote-i-o-module-new","provider":"SpareOil Automation","version":"1.0","type":"link"}