{"product_id":"f2do801-hima-safety-digital-output-module-new-original-stock","title":"F2DO801 HIMA Safety Digital Output Module | New \u0026 Original Stock","description":"\u003ch2\u003eHIMA F2DO801 HIMatrix Safety Systems\u003c\/h2\u003e\n\u003cp\u003eConfigured for executing final switching commands via SafeEthernet in safety-related controllers, the \u003cstrong\u003eHIMA F2DO801\u003c\/strong\u003e (\u003cstrong\u003eF2DO801\u003c\/strong\u003e Safety Digital Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF2DO801\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSafety Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Certification\u003c\/td\u003e\n\u003ctd\u003eIEC 61508 SIL 3, IEC 61511 SIL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 independent fail-safe relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eRelay-based, electrically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC, -15% to +20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input\u003c\/td\u003e\n\u003ctd\u003e0.6 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current per Channel\u003c\/td\u003e\n\u003ctd\u003e0.5 A (short-circuit proof)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e20 ms or greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 x RJ-45, 10BASE-T\/100BASE-Tx with integrated switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Fuse\u003c\/td\u003e\n\u003ctd\u003e10 A time-lag (T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e14.4 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e207 x 114 x 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSIL3 Certification and Fail-Safe State Execution\u003c\/h3\u003e\n\u003cp\u003eThe F2DO801 is cross-examined and validated under strict structural guidelines to sustain compliance with SIL3 certification metrics. Operating via a \"de-energize to trip\" processing mechanism, the unit commands all 8 internal relays to drop out and assume a de-energized safe state if a critical system fault occurs. Integrated galvanic isolation separates the logic components from the field terminal blocks, preventing external faults from destabilizing the internal safety controller. If a localized, channel-specific failure is found through real-time load fault diagnostics, the internal logic executes a single-channel fail-safe state execution, maintaining complete availability across the remaining non-faulted circuits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the F2DO801 manage localized channel faults versus complete module faults?\u003c\/p\u003e\n\u003cp\u003eA: Internal diagnostic loops continuously monitor for short circuits, open circuits, and load faults. A channel-specific problem causes only the affected channel relay to drop out, while a system-wide hardware failure causes the module to drop power to all 8 safety relay outputs.\u003c\/p\u003e\n\u003cp\u003eQ: Can the internal switch on the Ethernet interfaces be configured to handle safe communication traffic?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 2 x RJ-45 interfaces operate on 10\/100BASE-Tx networks and use SafeEthernet data encapsulation to verify packet integrity and latency requirements before driving any output load commands.\u003c\/p\u003e\n\u003cp\u003eQ: What are the external circuit protection specifications for the module power distribution?\u003c\/p\u003e\n\u003cp\u003eA: The module power lines must be protected upstream by an external 10 A time-lag (T) fuse, and input power must originate from a power supply unit providing safe insulation per IEC 61131-2.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure and Environmental Limits:\u003c\/strong\u003e Install the IP20-rated metal housing inside an industrial cabinet that provides protection from ambient dirt and conductive moisture to stay within the 0 to 60 deg C operational limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e Secure the heavy-gauge earthing connection directly to the low-impedance ground bar using the integrated earthing screw on the metal body.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling and Separation:\u003c\/strong\u003e Route the SafeEthernet RJ-45 communication cables separate from the 24 VDC relay power output wiring to minimize signal distortion and electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block Wiring:\u003c\/strong\u003e Ensure all field conductors are correctly terminated and strain-relieved to prevent mechanical tension on the internal switching components.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43425819557978,"sku":"F2DO801","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/271_ab49b21f-9a25-4ee3-9789-ead8cf9b2bc7.jpg?v=1779936963","url":"https:\/\/www.spareoil.com\/products\/f2do801-hima-safety-digital-output-module-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}