{"product_id":"f3aio8-401-hima-analog-input-output-module-new-stock","title":"F3AIO8\/401 HIMA Analog Input Output Module | New Stock","description":"\u003ch2\u003eHIMA F3AIO8\/401 HIMatrix\/HIMax Safety Series\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA F3AIO8\/401\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF3 AIO 8\/4 01\u003c\/strong\u003e Remote I\/O Module, serves as the primary \u003cstrong\u003eF3AIO8\/401\u003c\/strong\u003e Analog Input\/Output (I\/O) Module utilized to execute continuous signal processing across HIMatrix and HIMax safety platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3AIO8\/401 (Part No. 982200409)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e20.6 x 9.3 x 11.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption \/ Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e8 channels (current\/voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e8 channels (current\/voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003e0-10 VDC, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit or 16-bit A\/D and D\/A conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+-0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 V RMS channel-to-ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eBuilt-in fault detection, open-loop monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 samples per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;=10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Tolerance\u003c\/td\u003e\n\u003ctd\u003e5-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, TUV approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHigh Reliability Safety Control (SIS)\u003c\/h3\u003e\n\u003cp\u003eThe module instrumentation architecture incorporates SIL 3 certification parameters to establish full loop signal integrity across concurrent input and output stages. The underlying logic framework executes a triple modular redundancy (TMR) 2oo3 architecture voting loop inside the dual A\/D and D\/A converter channels to prevent signal drift from corrupting safety variable values. High galvanic isolation limits common-mode electrical noise and inductive feedback surges up to 1500 V RMS channel-to-ground, enforcing immediate fail-safe state execution through the safety controller bus whenever terminal thresholds or loop diagnostics register abnormal parameters.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module handle fault monitoring on the active 4-20 mA output loops?\u003c\/p\u003e\n\u003cp\u003eA: The internal diagnostic systems perform continuous open-loop monitoring and read-back validation, comparing the commanded execution variable against the actual field current to detect broken lines instantly.\u003c\/p\u003e\n\u003cp\u003eQ: Can channels be configured independently for different signal levels like 0-10 VDC and 4-20 mA?\u003c\/p\u003e\n\u003cp\u003eA: Yes, individual channels are software-configurable via the system programming interface, allowing mixed voltage and current instrumentation paths on the same hardware block.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module assembly onto a standard symmetrical DIN-rail profile inside an electrical cabinet ensuring that the structural mounting latch engages completely. Route all low-voltage analog input and output cables through dedicated, shielded terminal wiring ducts that are completely segregated from high-current AC motor supply circuits or switching links. Instrumentation cable shield drain wires must connect to the central safety earth ground busbar at a single connection point to avoid generating circulating ground currents. Maintain nominal vertical spacing above and below the IP20 enclosure to ensure uninhibited convection air currents for internal thermal management.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43484611543130,"sku":"F3AIO8\/401","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/298._6b8f6a24-0009-473b-bb7f-d644e065673b.jpg?v=1781233503","url":"https:\/\/www.spareoil.com\/products\/f3aio8-401-hima-analog-input-output-module-new-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}