{"product_id":"f3yc08-0n-fa-m3-yokogawa-transistor-output-module","title":"F3YC08-0N FA-M3 Yokogawa Transistor Output Module","description":"\u003ch2\u003eYokogawa F3YC08-0N FA-M3 Transistor Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed digital switching in FA-M3 PLC chassis architectures, the \u003cstrong\u003eYokogawa F3YC08-0N\u003c\/strong\u003e (\u003cstrong\u003eF3YC08\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution. The module drives field actuators, solenoid valves, and indicator lamps through 8 independent solid-state transistor output channels. Mounted directly onto the local or expansion backplane base unit, the hardware accepts control signals from the central sequence CPU and switches externally supplied 24 VDC loads with sub-millisecond response times.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3YC08-0N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.13 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e28.9 mm W x 100 mm H x 83.2 mm D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3 W maximum (5 VDC backplane bus supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 transistor outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Load Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptical isolation between field logic and backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Speed\u003c\/td\u003e\n\u003ctd\u003e1 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation Integration\u003c\/h3\u003e\n\u003cp\u003eThe F3YC08-0N module employs optocoupler isolation barriers between the internal 5 VDC system logic and external 24 VDC output terminal blocks. When operating in control racks containing sensitive analog input loops carrying 4-20 mA HART loop protocol signals or millivolt CJC (cold junction compensation) temperature inputs, the solid-state switching architecture eliminates inductive contact arcing and high-frequency EMI transients. Channel grouping and backplane galvanic separation shield the main CPU logic from field-side voltage spikes during rapid inductive load switching.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What protective measures activate if an external field load draws current exceeding the 0.5 A per channel limit?\u003c\/p\u003e\n\u003cp\u003eA: Integrated overcurrent and short-circuit protection circuits limit output current flow to prevent thermal destruction of internal switching transistors and backplane logic paths.\u003c\/p\u003e\n\u003cp\u003eQ: Can the F3YC08-0N directly switch AC inductive loads without interposing devices?\u003c\/p\u003e\n\u003cp\u003eA: No. The transistor output architecture functions exclusively with DC voltage loads rated up to 24 VDC. AC loads require intermediate electromechanical relays or external solid-state switches.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping permitted for this module during active PLC rack operation?\u003c\/p\u003e\n\u003cp\u003eA: No. Disconnect all primary power to the FA-M3 base chassis and field power sourcing terminals before inserting or removing the output card.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block Wiring:\u003c\/strong\u003e Connect external 24 VDC field power sources using properly sized copper conductors and secure terminal screws to avoid high-resistance contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive Load Flyback Protection:\u003c\/strong\u003e Install external freewheeling diodes directly across DC inductive field loads (such as solenoid coils) to absorb reverse inductive kickback spikes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Practices:\u003c\/strong\u003e Bond the FA-M3 base unit protective earth (PE) terminal to the panel grounding bar using a low-impedance grounding braid.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Spacing:\u003c\/strong\u003e Maintain a clear vertical space of at least 50 mm above and below the module rack to support air circulation and prevent heat accumulation inside the enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43796442841178,"sku":"F3YC08-0N","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/397._aac5e424-7788-4c94-b1fe-e4ebbe93c34a.jpg?v=1786070731","url":"https:\/\/www.spareoil.com\/products\/f3yc08-0n-fa-m3-yokogawa-transistor-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}