{"product_id":"f3yd64-1f-yokogawa-fa-m3-64-channel-transistor-output-module","title":"F3YD64-1F Yokogawa FA-M3 64-Channel Transistor Output Module","description":"\u003ch2\u003eYokogawa F3YD64-1F FA-M3 Transistor Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete field actuation in FA-M3 PLC platforms, the \u003cstrong\u003eYokogawa F3YD64-1F\u003c\/strong\u003e (\u003cstrong\u003eF3YD64-1F\u003c\/strong\u003e Transistor Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3YD64-1F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e35.0 mm x 130.0 mm x 100.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6.0 W approx. (supplied via 5 VDC backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e64 transistor outputs (Sink-type DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (range 20.4 to 28.8 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e0.1 A per channel maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Current Capacity\u003c\/td\u003e\n\u003ctd\u003e3.2 A per common terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 0.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptical isolation between channels and internal logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLED indicators per output channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Signal Isolation and High-Density Switching Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe module executes discrete state control through 64 sink-type transistor output channels organized across high-density terminal banks. Integrated optical isolation barriers physically disconnect field-side 24 VDC switching circuits from the internal backplane logic bus. This configuration prevents high-voltage surges and common-mode noise from entering the primary CPU card while delivering response times below 0.5 ms. Built-in protection logic handles inductive switching noise, maintaining signal integrity during rapid state transitions across external solenoid valves and auxiliary relays.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the current loading limitations when operating all 64 output channels simultaneously?\u003c\/p\u003e\n\u003cp\u003eA: Each individual output channel supports a maximum current load of 0.1 A at 24 VDC. Field installers must ensure that total current draw per common terminal bank does not exceed 3.2 A to avoid thermal overload.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle inductive voltage spikes during high-speed transistor switching?\u003c\/p\u003e\n\u003cp\u003eA: Internal optical couplers isolate field circuits from backplane logic, but external inductive loads (such as DC relay coils) require external flyback diodes installed directly across the field device terminals to suppress inductive voltage transients.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module directly into a free I\/O slot on the FA-M3 base unit. Ensure backplane connectors align correctly before pushing the module firmly into position, and tighten the retaining screw to lock the assembly to the DIN rail frame.\u003c\/p\u003e\n\u003cp\u003eTerminate field wiring using the 64-point connector block. Connect the external 24 VDC power supply to the designated power terminals, ensuring correct polarity for sink-type transistor operation. Route field output cables separately from high-voltage AC lines to prevent electromagnetic cross-talk. Maintain adequate enclosure cabinet ventilation to dissipate internal heat when all 64 channels operate at maximum current capacity.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43816581398618,"sku":"F3YD64-1F","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/620_663f9a79-74e0-46bb-96fb-7ecffcdd0d02.jpg?v=1786330747","url":"https:\/\/www.spareoil.com\/products\/f3yd64-1f-yokogawa-fa-m3-64-channel-transistor-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}