{"product_id":"f3yd64-1p-yokogawa-transistor-output-modules","title":"F3YD64-1P Yokogawa Transistor Output Modules","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa F3YD64-1P\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF3YD64\u003c\/strong\u003e Transistor Output Module, operates as a dedicated hardware component for high-density digital output execution within Yokogawa FA-M3 PLC series platforms. Configured with 64 solid-state switching points, this module provides direct electrical actuation for external field devices such as solenoids, relays, and valves.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3YD64-1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e28.9 mm x 85.1 mm x 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e275 mA (5 V DC internal backplane draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eTransistor (sink type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e64 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Line Type\u003c\/td\u003e\n\u003ctd\u003e8 points \/ common (8 points per common line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Method\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V AC for one minute (external terminals to internal circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Load Voltage\u003c\/td\u003e\n\u003ctd\u003e12 to 24 V DC nominal (10.2 to 26.4 V DC operating range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Current\u003c\/td\u003e\n\u003ctd\u003e0.1 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2 ms (turn-on \/ turn-off latency)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e12 to 24 V DC, 95 mA requirement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Backplane Communication Velocity\u003c\/h3\u003e\n\u003cp\u003eDesigned for compatibility with the FA-M3 high-speed backplane bus architecture, this module processes output commands with a response latency under 0.2 ms, facilitating deterministic network performance. The integration of photocoupler isolation establishes a localized electrical barrier, preventing transient field noise from degrading backplane bus communication velocity licenses. This high-density scaling provides 64 discrete points inside a single slot footprint while preserving signal separation via an 8 points per common distribution grid.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the exact requirements and load limitations for the external power supply connection?\u003c\/p\u003e\n\u003cp\u003eA: The F3YD64-1P demands an independent external power supply operating between 12 and 24 V DC capable of supplying at least 95 mA to drive the internal photocoupler and output switching stages. This external voltage must be sustained within the 10.2 to 26.4 V DC tolerance band during full load switching.\u003c\/p\u003e\n\u003cp\u003eQ: How is the common line return current distributed across the 64 channels?\u003c\/p\u003e\n\u003cp\u003eA: The module splits its 64 channels into groupings of 8 points per common line. The cumulative current load passing through any single common return pin must not exceed the aggregate limit dictated by the 0.1 A per channel baseline and standard connector pins ratings.\u003c\/p\u003e\n\u003cp\u003eQ: Does the sinking configuration dictate specific polarity during field installation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, as a sink-type (NPN) transistor module, the external load must be connected between the positive rail of the DC power supply and the specific module output terminal. The module switches the low side of the circuit to the common ground when activated.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Wiring and Wire Stripping:\u003c\/strong\u003e Terminate all 64 output points using the multi-pin high-density connector interface. Verify all wire crimps are secure and that wire routing does not apply downward stress on the front face of the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparation of Signal Lines:\u003c\/strong\u003e Keep the 12-24 V DC digital output lines separated from high-voltage AC mains and motor drive cables within the wire ducts to prevent electromagnetic induction from triggering intermittent output states.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management in Cabinets:\u003c\/strong\u003e Ensure adequate clearance around the FA-M3 base unit rack to accommodate the 3 W heat dissipation profile of the module. Maintain vertical orientation during rack mounting to allow unobstructed convective heat dissipation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43517919133786,"sku":"F3YD64-1P","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/397._79d14dfc-23d3-4459-9ff6-a05c22f173b1.jpg?v=1781761748","url":"https:\/\/www.spareoil.com\/products\/f3yd64-1p-yokogawa-transistor-output-modules","provider":"SpareOil Automation","version":"1.0","type":"link"}