{"product_id":"fc-gmmd16-honeywell-safety-manager-16-channel-i-o-module","title":"FC-GMMD16 Honeywell Safety Manager 16-Channel I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-GMMD16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density Mixed Digital I\/O Module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafety Manager SC (S300 IOTA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. This versatile module optimizes cabinet space by combining 8 Digital Inputs and 8 Digital Outputs within a single chassis slot. It interfaces field devices—such as limit switches, sensors, and solenoids—directly with the Safety Manager controller. Certified for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL3 applications\u003c\/strong\u003e, the FC-GMMD16 ensures uncompromising safety and operational logic for critical process loops. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original in Factory Packing\u003c\/strong\u003e, providing the baseline reliability required for modern safety-instrumented systems (SIS).\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-GMMD16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (8 Digital Inputs + 8 Digital Outputs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Dry Contact or Voltage Input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Solid-state \/ Relay (Configuration dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Switching Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A per output channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Certification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL3 (IEC 61508 Compliant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanic (Channel-to-channel and bus isolation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHot-Swap Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e240 × 109 × 80 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Cabinet Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe mixed I\/O architecture reduces the number of individual modules required for a safety loop. By consolidating 8 inputs and 8 outputs onto a single card, engineers significantly decrease rack space requirements and total hardware costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Safety Integrity (SIL3):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery channel incorporates self-testing diagnostics to meet stringent IEC 61508 standards. This module maintains the highest probability of failure on demand (PFD) performance, ensuring critical safety actions execute flawlessly in emergency shutdown (ESD) scenarios.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Environmental Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard PLC hardware, the FC-GMMD16 operates in extreme temperatures ranging from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e–40°C to +85°C\u003c\/strong\u003e. This capability enables installation in remote instrument enclosures (RIE) located in harsh climates without requiring external climate control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Fault Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in line monitoring detects open circuits and shorted field wiring immediately. This proactive diagnostic capability allows maintenance teams to identify and resolve field-side issues before they lead to a dangerous failure or an unplanned process trip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Drive Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach output channel supports up to 2 A. This allows the module to drive large solenoids and interposing relays directly, simplifying the electrical design and reducing the need for additional external amplification components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Disruptive Hot-Swap:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware design permits module replacement while the system remains under power. Technicians can swap faulty units without halting the safety controller, ensuring 24\/7 process availability and minimized maintenance windows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the FC-GMMD16 drive solenoids directly without interposing relays?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Each of the 8 digital output channels supports up to 2 A at 24 VDC. This capacity is sufficient for most industrial solenoids and actuators, allowing for a more direct and reliable control loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of field devices can I connect to the 8 input channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe input channels accept standard 24 VDC signals. They work perfectly with dry contacts (pushbuttons, limit switches) or active voltage sensors, providing flexible interfacing for various safety-critical monitoring points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle a short circuit on a field output?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FC-GMMD16 features integrated over-current protection. If it detects a short circuit, the module protects the internal circuitry and triggers a diagnostic fault alarm at the controller to alert the operator immediately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine Honeywell original part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. We ship only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFC-GMMD16 modules in their original factory-sealed Honeywell packaging. Every unit includes our 12-month warranty for complete peace of mind.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43190449438810,"sku":"FC-GMMD16","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/416._6c863334-1975-4308-838b-eb33c6ebff33.jpg?v=1775609879","url":"https:\/\/www.spareoil.com\/products\/fc-gmmd16-honeywell-safety-manager-16-channel-i-o-module","provider":"SpareOil Automation","version":"1.0","type":"link"}