{"product_id":"fc-mcar-01-honeywell-safety-manager-i-o-mounting-plate","title":"FC-MCAR-01 Honeywell Safety Manager I\/O Mounting Plate","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-MCAR-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the essential physical and electrical framework for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafety Manager\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFail Safe Control (FSC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed architectures. This high-integrity Module Carrier (MCAR) functions as the backbone for I\/O module clusters, facilitating high-speed communication and heavy-duty power distribution. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your safety system meets the stringent\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 3 (IEC 61508)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements necessary to protect high-risk industrial assets and personnel.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-MCAR-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModule Carrier (MCAR) \/ Mounting Plate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Certification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL 3 (IEC 61508), TÜV (EN 50128)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (-45% to +32% Tolerance)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum 40A (Supply Rail)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Logic Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum 4A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-42°C to +70°C (-40°F to +158°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40% to 90%, non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePanel or Rack Mounting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, Class I Div 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Capacity Power Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FC-MCAR-01 features an integrated backplane capable of handling up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e40A on the main supply rail\u003c\/strong\u003e. This massive current capacity allows for high-density I\/O configurations, ensuring that even the most demanding analog and digital modules receive stable 24 VDC without significant voltage drops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Distributed Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe carrier architecture optimizes signal paths between installed I\/O modules and the central safety controller. This ensures millisecond-level responsiveness required for emergency shutdown (ESD) and fire and gas (F\u0026amp;G) logic execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Thermal Endurance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for unconditioned industrial environments, the module thrives in temperatures from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-42°C to +70°C\u003c\/strong\u003e. Whether installed in arctic conditions or desert refineries, the FC-MCAR-01 maintains mechanical and electrical integrity where standard racks fail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Stability in High-Vibration Zones:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure mechanical latching systems and robust mounting plates prevent accidental module dislodgment. This makes the FC-MCAR-01 ideal for installation near heavy rotating machinery or on offshore platforms subject to constant structural vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL 3 Certified Safety Backbone:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard commercial racks, this carrier undergoes rigorous TÜV certification. It meets IEC 61508 standards, providing a verified \"fail-safe\" infrastructure that eliminates common-cause failures at the mounting level.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix different types of I\/O modules on a single FC-MCAR-01?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The FC-MCAR-01 serves as a universal mounting platform for various Honeywell Safety Manager I\/O modules. You can populate the slots with a mix of Analog and Digital cards depending on your specific safety loop requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"Revision 1\" status for the backplane?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRevision 1 identifies the high-current version of the carrier, supporting up to 40A. This revision ensures compatibility with modern, power-hungry universal I\/O modules and provides better thermal dissipation compared to legacy mounting plates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the FC-MCAR-01 require a specific mounting orientation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile it supports both panel and rack mounting, you must ensure adequate airflow across the installed modules. Honeywell typically recommends vertical mounting in cabinets to facilitate natural convection cooling, especially when operating at the upper end of the temperature range (+70°C).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy should I purchase a brand new carrier for a system expansion?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe backplane connectors and power rails on the FC-MCAR-01 are subject to \"fretting corrosion\" and electrical wear over decades of service. A\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunit guarantees pristine contact surfaces and maximum dielectric strength, which are vital for maintaining the SIL 3 rating of your safety instrumented system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":42870911336538,"sku":"FC-MCAR-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/39._10885dce-0586-4bc9-b2eb-86a1dbf51956.jpg?v=1776329732","url":"https:\/\/www.spareoil.com\/products\/fc-mcar-01-honeywell-safety-manager-i-o-mounting-plate","provider":"SpareOil Automation","version":"1.0","type":"link"}