{"product_id":"fc-sdol-0424-honeywell-safety-manager-24vdc-1a-output","title":"FC-SDOL-0424 Honeywell Safety Manager 24VDC 1A Output","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-SDOL-0424\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Hardware Version V1.2) acts as a high-integrity Safe Digital Output Loop Monitored (LM) module for the Honeywell Fail-Safe Control (FSC) system. This module manages critical final elements, including solenoid valves, actuators, and ESD relays, within a Safety Instrumented System (SIS). It executes fail-safe transitions to a de-energized state upon fault detection or logic commands. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring full compliance with SIL 3 safety requirements per IEC 61508.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe FC-SDOL-0424 integrates robust solid-state switching with advanced diagnostic circuitry to maintain loop integrity.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Independent Output Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Current (Channel)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Total Load\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.6 A (Thermal Limit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL 3 Capable (IEC 61508)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMonitoring\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLoop Monitoring (Short circuit, Lead breakage)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Inductance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Capacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 μF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Drop\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 1.3 V @ 1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 HP, 3U (Compact Modular Design)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Loop Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module continuously scans the field loop for short circuits and lead breakages. This monitoring ensures that the safety loop remains ready to execute an Emergency Shutdown (ESD) at all times, preventing \"hidden\" failures in the wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Inductive Load Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically designed for heavy industrial actuators, the FC-SDOL-0424 manages load inductance up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5 H\u003c\/strong\u003e. This eliminates the need for external suppression components in most standard solenoid applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Self-Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware limits the total module load to 3.6 A. This thermal management prevents internal overheating, protecting the module and adjacent I\/O cards from heat-induced degradation in high-density cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Watchdog (WDG):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA dedicated watchdog input monitors processor health. The module only executes output commands when internal system integrity is verified, providing an additional layer of protection against logic errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does \"Loop Monitored\" mean for the FC-SDOL-0424?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt means the module actively checks the integrity of the field wiring even when the output is off. It detects if a wire breaks or if a short circuit occurs between the module and the final element (e.g., a valve).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module drive 1A on all four channels simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile each individual channel supports 1A, the total module load must not exceed 3.6A due to thermal constraints. If you run all four channels, you must balance the load to stay within this safety limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the FC-SDOL-0424 V1.2 backward compatible with older FSC versions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, version V1.2 maintains compatibility with standard FSC racks, but you must verify that your system software supports the specific diagnostic features of this hardware revision.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIn what condition is this module supplied?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe supply the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-SDOL-0424 as 100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein original factory packaging. It includes a 12-month warranty and full technical documentation for SIL 3 verification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":42870908977242,"sku":"FC-SDOL-0424","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/519_d5fc93ad-228b-4cac-98c9-4df33b99ba22.jpg?v=1776670741","url":"https:\/\/www.spareoil.com\/products\/fc-sdol-0424-honeywell-safety-manager-24vdc-1a-output","provider":"SpareOil Automation","version":"1.0","type":"link"}