{"product_id":"fc-tdo-1624-honeywell-safety-manager-sc-16-ch-do-module","title":"FC-TDO-1624 Honeywell Safety Manager SC 16-Ch DO Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-TDO-1624\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(often associated with the FSC\/Safety Manager line) serves as a high-density, 16-channel Safe Digital Output module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafety Manager SC (S300 IOTA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. This module converts logic commands from the safety controller into 24VDC signals to drive critical field actuators, including solenoids, interposing relays, and emergency shutdown valves. Engineered for the most demanding Safety Instrumented Functions (SIF), it carries a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL3 certification\u003c\/strong\u003e, ensuring maximum risk reduction in hazardous process environments. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, maintaining the highest integrity for your safety-critical infrastructure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-TDO-1624 \/ FC-TSDO-1624\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Independent Digital Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Switching Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 2 A per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Certification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL3 (IEC 61508 Compliant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-Channel \u0026amp; Channel-to-System Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in line monitoring and fault detection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHot-Swap Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 (Cabinet Installation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e240 × 109 × 80 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Actuation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16-channel architecture doubles the output capacity compared to standard 8-channel modules. This allows engineers to manage extensive valve and motor control arrays within a single I\/O slot, significantly reducing cabinet footprint and hardware costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL3 Safety Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery channel features redundant diagnostic paths to meet strict SIL3 standards. The module ensures that critical safety actions—such as isolating a fuel line—execute correctly even in the presence of internal component wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Line Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module performs continuous \"dark tests\" to verify loop integrity without cycling the field equipment. It detects open circuits or shorted wiring instantly, providing real-time feedback to the HMI to prevent \"hidden\" faults from compromising the safety loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Thermal Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial-grade components allow the module to operate from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e–40°C to +85°C\u003c\/strong\u003e. This eliminates the requirement for specialized HVAC systems in remote instrument enclosures (RIE) located in harsh geographic regions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Galvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuperior isolation barriers protect the central processor from field-side electrical surges and ground loops. This prevents a single failure at a field solenoid from cascading through the entire Safety Manager rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOnline Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHot-swap capability enables technicians to replace modules under power. This feature eliminates the need for process shutdowns during routine maintenance or hardware upgrades, ensuring 24\/7 availability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the FC-TDO-1624 drive high-current solenoids directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Each channel supports up to 2 A of switching current, which is sufficient to drive most industrial 24VDC solenoids and actuators without the need for interposing relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support line monitoring for both \"ON\" and \"OFF\" states?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module includes built-in diagnostics that monitor the health of the output circuit and field wiring, providing fault detection for both open lines and short circuits to ensure the loop is ready when a safety trip is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between FC-TDO and FC-TSDO nomenclature?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the functions are virtually identical within the Safety Manager SC series, \"TSDO\" explicitly highlights \"Safe\" digital output. The FC-TDO-1624 remains the high-density standard for S300 IOTA safety subsystems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine Honeywell product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe only sell\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell modules. Each unit arrives in its original factory packaging with a verified serial number for traceability and quality assurance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43187911065690,"sku":"FC-TDO-1624","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/409_342cf3be-2648-4b33-9391-68624ebebb55.jpg?v=1775551178","url":"https:\/\/www.spareoil.com\/products\/fc-tdo-1624-honeywell-safety-manager-sc-16-ch-do-module","provider":"SpareOil Automation","version":"1.0","type":"link"}