{"product_id":"fc-tsgash-1624p-honeywell-safety-manager-digital-i-o-board","title":"FC-TSGASH-1624P Honeywell Safety Manager Digital I\/O Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-TSGASH-1624P\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-integrity physical interface between discrete field devices and the central safety controller. Engineered specifically for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Safety Manager\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFail Safe Control (FSC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatforms, this 16-channel Field Termination Assembly (FTA) handles critical ON\/OFF signal transmissions for monitoring and actuation. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your Safety Instrumented System (SIS) utilizes factory-certified hardware to maintain peak operational uptime and regulatory compliance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-TSGASH-1624P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital I\/O Field Termination Assembly (FTA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Discrete Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLogic Thresholds\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh: \u0026gt;15VDC; Low: \u0026lt;4VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndividual per-channel current limiting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-Bus Galvanic Isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard DIN EN rail (Universal snap-in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40 °C to +70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, IEC; Suitable for Class I, Div 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLocalized Short-Circuit Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FC-TSGASH-1624P utilizes an individual current-limiting design for every channel. If a field-side sensor or actuator experience a short circuit, the board isolates that specific loop. This architecture prevents a singular fault from collapsing the 24VDC power rail for the remaining 15 channels, ensuring continuous system availability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-grade galvanic isolation separates the field wiring from the sensitive system bus. This barrier blocks electrical transients, electromagnetic interference (EMI), and ground loops from reaching the safety processor, maintaining the integrity of the logic execution in high-noise industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarsh Environment Readiness:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module carries an industrial temperature rating of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e–40 °C to +70 °C\u003c\/strong\u003e. Its ruggedized construction allows for reliable operation on offshore platforms, chemical processing plants, and desert refineries where unconditioned cabinets are common.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Status Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated LED indicators provide immediate visual feedback for each of the 16 channels. Technicians can identify signal states and fault conditions at a glance, significantly reducing Mean Time to Repair (MTTR) during critical maintenance windows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Field Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure screw terminals handle rugged field wiring, while a specialized SIC Connector manages the high-speed system interface via SICC interconnect cables. This dual-connection strategy simplifies installation in crowded DIN rail enclosures and ensures vibration-resistant contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the FC-TSGASH-1624P handle both inputs and outputs?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. This module functions as a Digital Input\/Output Field Termination Assembly, allowing it to interface with both discrete sensors (inputs) and actuators like solenoids or relays (outputs) within the Safety Manager environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this board compatible with legacy Honeywell FSC systems?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAbsolutely. The FC-TSGASH-1624P maintains full compatibility with both the legacy Fail Safe Control (FSC) systems and the modern Safety Manager and Safety Manager SC platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit support hot-swapping?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the board itself is a passive termination assembly, it supports live maintenance procedures when used in conjunction with redundant Safety Manager I\/O modules, provided you follow standard site-specific safety protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the mounting requirements for Class I, Div 2 areas?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board is certified for Class I, Div 2 hazardous locations. You must install it within a suitable enclosure that meets the local electrical code and environmental protection requirements (IP\/NEMA) for that specific hazardous zone.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":42870912024666,"sku":"FC-TSGASH-1624P","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/37.jpg?v=1776329195","url":"https:\/\/www.spareoil.com\/products\/fc-tsgash-1624p-honeywell-safety-manager-digital-i-o-board","provider":"SpareOil Automation","version":"1.0","type":"link"}