{"product_id":"fc-usi-0002-honeywell-safety-manager-system-module-original","title":"FC-USI-0002 Honeywell Safety Manager System Module Original","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-USI-0002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a Universal Safety Interface (USI) within the Honeywell Safety Manager architecture. This mission-critical module bridges the gap between field-side digital devices and the core control processor, facilitating high-speed, secure signal transmission. It plays a vital role in Emergency Shutdown (ESD) and Fire \u0026amp; Gas (F\u0026amp;G) applications by ensuring data integrity across redundant communication channels. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original in factory packing\u003c\/strong\u003e, ensuring your safety-instrumented system (SIS) operates with maximum reliability and factory-certified components.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-USI-0002 \/ Universal Safety Interface CC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafety Manager System Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 – 15 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL-Rated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 × 140 × 60 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 Kg (Net Weight0.35 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL, CE, CSA, SIL Certified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFault-Tolerant Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FC-USI-0002 supports a fully redundant architecture. This dual-channel design ensures that the safety system maintains continuous uptime even if a single communication path sustains a fault, preventing costly and dangerous unplanned process shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Environmental Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for the harshest industrial sectors, this module operates reliably in temperatures ranging from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-40°C to +70°C\u003c\/strong\u003e. This thermal durability allows for deployment in remote oil \u0026amp; gas sites and non-climate-controlled processing facilities without risk of signal drift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Precision Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced internal circuitry filters out electromagnetic interference (EMI) and radio frequency interference (RFI). By stabilizing field signals, the USI-0002 prevents false trips and ensures that only valid safety data reaches the control logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Safety Manager Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTailored specifically for the Honeywell Safety Manager ecosystem, the FC-USI-0002 facilitates rapid commissioning. It communicates natively with the system backplane, reducing the time required for software configuration and loop testing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact, Modular Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe lightweight and space-saving design permits high-density mounting within standard Safety Manager chassis. This modularity allows engineers to maximize I\/O capacity within confined control room cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary role of the FC-USI-0002 in a Safety Manager system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FC-USI-0002 acts as a universal gateway for safety signals. It standardizes data from various field devices and transmits it securely to the Safety Manager’s central processing unit, maintaining the strict timing required for SIL-rated safety loops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support hot-swapping during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, when utilized within a redundant Safety Manager configuration, you can replace the FC-USI-0002 while the system is live. This ensures maintenance does not interrupt your plant's safety coverage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the FC-USI-0002 handle both input and output interfacing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"Universal\" designation indicates its broad compatibility with the Safety Manager's internal bus and various field signal types. However, always refer to your specific system topology to ensure the interface matches your I\/O module requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify that this unit is New and Original?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvery Honeywell FC-USI-0002 we provide comes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New in original Honeywell factory packing\u003c\/strong\u003e. Each unit includes a verified serial number and a 12-month factory warranty, protecting your investment from the risks of refurbished or surplus stock.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43210051616858,"sku":"FC-USI-0002","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/111_666db5db-fd91-4494-8b2b-421180c929f8.jpg?v=1776065658","url":"https:\/\/www.spareoil.com\/products\/fc-usi-0002-honeywell-safety-manager-system-module-original","provider":"SpareOil Automation","version":"1.0","type":"link"}