{"product_id":"foxboro-fbm219-p0917lh0c-i-a-series-discrete-i-o-module","title":"Foxboro FBM219 P0917LH0C I\/A Series Discrete I\/O Module","description":"\u003ch2\u003eFoxboro FBM219 P0917LH0C I\/A Series Discrete I\/O Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro FBM219 P0917LH0C\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFBM219\u003c\/strong\u003e Discrete I\/O Interface Module, operates as a dedicated hardware component for high-density digital signal processing and event recording within Foxboro I\/A Series DCS networks. The module monitors field contact states and drives discrete control outputs across dual redundant 24 VDC backplane power buses.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFBM219 P0917LH0C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro (Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.6 cm x 11.0 cm x 11.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e8.5 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e32 discrete channels (24 inputs, 8 outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Support\u003c\/td\u003e\n\u003ctd\u003e30 VDC, 125 VDC, 120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ms time-stamping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Filtering\u003c\/td\u003e\n\u003ctd\u003eSoftware-selectable 4 ms to 255 ms debounce\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e600 VAC channel-to-earth, group-to-group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC redundant input via baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Sequence of Events Recording\u003c\/h3\u003e\n\u003cp\u003eThe FBM219 P0917LH0C incorporates galvanically isolated group structures rated for 600 VAC isolation between input channels and internal logic circuits. This isolation suppresses common-mode ground noise and prevents high-voltage field surges from degrading DCS backplane communications. Integrating continuous 1 ms Sequence of Events (SOE) resolution, the internal digital processing unit timestamps state transitions at the module level prior to transmitting buffered diagnostic packets over the system bus.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module process different field voltage levels across the 32 channels?\u003c\/p\u003e\n\u003cp\u003eA: Input channels accept field discrete signals operating at 30 VDC, 125 VDC, or 120\/240 VAC. The module conditions these signals down to system logic levels (High \u0026gt;15 VDC, Low \u0026lt;5 VDC) while maintaining galvanic isolation across channel groups.\u003c\/p\u003e\n\u003cp\u003eQ: Can the FBM219 be hot-swapped during active system operations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, operators can perform live hot-swapping on the active baseplate without disrupting adjacent operational I\/O modules or interrupting backplane communication traffic.\u003c\/p\u003e\n\u003cp\u003eQ: What termination hardware is required to wire field devices to this module?\u003c\/p\u003e\n\u003cp\u003eA: The module requires interface integration with the dedicated P0917LH external termination assembly to correctly route field wiring to the backplane connectors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eObserve the following field installation procedures during system panel wiring and hardware integration:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eInsert the FBM219 module into its assigned baseplate slot until the upper and lower retaining latches lock firmly.\u003c\/li\u003e\n\u003cli\u003eRoute high-voltage AC field lines away from low-voltage digital signal wiring inside the enclosure raceways to minimize inductive coupling.\u003c\/li\u003e\n\u003cli\u003eTerminate field fieldbus cables directly to the associated P0917LH termination assembly according to channel assignment schematics.\u003c\/li\u003e\n\u003cli\u003eEnsure the enclosure maintains clean airflow and operates within the environmental temperature window of -20 deg C to +70 deg C.\u003c\/li\u003e\n\u003cli\u003eGround all cable shielding at the designated panel ground bus to provide a low-impedance earth return path for transient voltage spikes.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43931131052122,"sku":"P0917LH 0C","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/462._32cc03b0-3aa6-4a70-bf19-27fa0c38635a.jpg?v=1787899862","url":"https:\/\/www.spareoil.com\/products\/foxboro-fbm219-p0917lh0c-i-a-series-discrete-i-o-module","provider":"SpareOil Automation","version":"1.0","type":"link"}