{"product_id":"foxboro-fbmslt-fieldbus-h1-communication-module-invensys","title":"Foxboro FBMSLT Fieldbus H1 Communication Module Invensys","description":"\u003ch2 class=\"animating\"\u003eProduct Details\u003c\/h2\u003e\n\u003ch3 class=\"animating\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp class=\"animating\"\u003e\u003cspan class=\"animating\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"animating\"\u003eFoxboro FBMSLT\u003c\/strong\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance Fieldbus communication and analog output interface within the Invensys I\/A Series Distributed Control System (DCS).\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module bridges the gap between the control network and field devices by providing eight precise 4–20 mA output channels alongside robust\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"animating\"\u003eFOUNDATION Fieldbus H1\u003c\/strong\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003econnectivity.\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eWe provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"animating\"\u003e100% brand new, original factory stock\u003c\/strong\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eto ensure maximum uptime in mission-critical environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"animating\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 MB SDRAM, 32 MB Flash\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (Supports Redundant Feeds)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax 8.5 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Channels (4–20 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFOUNDATION Fieldbus H1, Modbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArchitecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle or Fault-tolerant Dual Processor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndependent current limiting per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompact rack-mounted, Hot-swappable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"animating\"\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"animating list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"animating\"\u003e\u003cstrong class=\"animating\"\u003eFault-Tolerant Reliability:\u003c\/strong\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eThe FBMSLT supports a dual-processor configuration.\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eThis architecture eliminates single points of failure,\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003emaintaining continuous process control even if one processor fails.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"animating\"\u003e\u003cstrong class=\"animating\"\u003eSeamless Maintenance:\u003c\/strong\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eThe hot-swappable design allows technicians to replace modules without powering down the system.\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eThis significantly reduces Mean Time to Repair (MTTR) in continuous processing plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"animating\"\u003e\u003cstrong class=\"animating\"\u003eSignal Integrity:\u003c\/strong\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eIndependent power regulation and electrical isolation for every channel prevent ground loops and protect the internal logic from field-side electrical surges.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"animating\"\u003e\u003cstrong class=\"animating\"\u003eAdvanced Diagnostics:\u003c\/strong\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eWhen paired with the optional F809F-Plus module,\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003ethe system delivers real-time health monitoring of the Fieldbus physical layer,\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eidentifying cable degradation or noise issues before they cause unplanned shutdowns.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"animating\"\u003e\u003cstrong class=\"animating\"\u003eSimplified Field Integration:\u003c\/strong\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eBy combining traditional 4-20 mA outputs with modern Fieldbus H1 protocols,\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003ethis module allows engineers to manage hybrid field device environments from a single slot.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"animating\"\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"animating list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"animating\"\u003e\u003cstrong class=\"animating\"\u003eIs this FBMSLT module supplied in original packaging?\u003c\/strong\u003e\u003cspan class=\"animating\"\u003eYes.\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eWe supply only\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"animating\"\u003e100% Brand New\u003c\/strong\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eoriginal Foxboro Invensys units.\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eEach module ships in its factory-sealed anti-static packaging to guarantee integrity and performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"animating\"\u003e\u003cstrong class=\"animating\"\u003eDoes the module support redundant power supplies?\u003c\/strong\u003e\u003cspan class=\"animating\"\u003eAbsolutely.\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eThe FBMSLT accepts 24 VDC redundant power inputs,\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring the module remains operational even if one primary power source fails.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"animating\"\u003e\u003cstrong class=\"animating\"\u003eCan I use this module to replace older I\/A Series output cards?\u003c\/strong\u003e\u003cspan class=\"animating\"\u003eThe FBMSLT is designed for the I\/A Series ecosystem.\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eHowever,\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eyou should verify your specific system software version and baseplate compatibility.\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003eOur technical team can assist with firmware compatibility checks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"animating\"\u003e\u003cstrong class=\"animating\"\u003eWhat is the primary benefit of the \"Independent Current Limiting\" feature?\u003c\/strong\u003e\u003cspan class=\"animating\"\u003eIt ensures that a short circuit or fault on one specific field device channel does not affect the operation or power stability of the remaining seven channels,\u003c\/span\u003e\u003cspan class=\"animating\"\u003e\u003cspan\u003e \u003c\/span\u003elocalized failure remains isolated.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43283873628250,"sku":"FBMSLT","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/338._e82797b7-f25c-472e-9988-44d13e5b9fe7.jpg?v=1777337898","url":"https:\/\/www.spareoil.com\/products\/foxboro-fbmslt-fieldbus-h1-communication-module-invensys","provider":"SpareOil Automation","version":"1.0","type":"link"}