{"product_id":"foxboro-p0901xt-02-evo-intelligent-transmitter-modules","title":"Foxboro P0901XT-02 Evo Intelligent Transmitter Modules","description":"\u003ch2\u003eFoxboro P0901XT-02 Intelligent Transmitter Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro P0901XT-02\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eP0901XT\u003c\/strong\u003e Intelligent Transmitter Module, operates as a dedicated hardware component for multi-variable process loop measurement within Foxboro Evo and I\/A Series DCS platforms. It converts dynamic process inputs for pressure, differential pressure, flow, and liquid level directly into a calibrated 4-20 mA analog output with digital signal overlays.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0901XT-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Foxboro compact transmitter assembly enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLoop-powered via nominal 24 VDC bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.15% of calibrated range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA analog with HART \/ FOUNDATION Fieldbus \/ PROFIBUS PA protocol overlay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP66 rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWetted Components\u003c\/td\u003e\n\u003ctd\u003eStainless steel \/ Hastelloy corrosion-resistant alloys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe P0901XT-02 transmits process parameters via 4-20 mA HART loop protocol telemetry, overlaying bi-directional digital command streams onto the analog current loop without interrupting continuous signal feedback. Internal galvanic isolation barriers decouple the sensing element circuitry from the field wiring loops, suppressing ground loop interference and cross-talk across multi-channel baseplates. Integrated cold junction compensation (CJC) processing and real-time internal self-diagnostics constantly monitor transducer integrity, ensuring high signal fidelity across FOUNDATION Fieldbus and PROFIBUS PA network segments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the P0901XT-02 module be hot-swapped while the field loop is energized?\u003c\/p\u003e\n\u003cp\u003eA: Field loop power must be disconnected prior to wiring or module removal to prevent electrical arcing and field bus signal disruption during maintenance.\u003c\/p\u003e\n\u003cp\u003eQ: How does the unit maintain reference accuracy across wide thermal variations?\u003c\/p\u003e\n\u003cp\u003eA: Internal digital microprocessors apply thermal compensation profiles against raw piezoresistive or capacitive sensor data to sustain +\/-0.15% accuracy from -40 to 85 deg C.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the P0901XT-02 securely using a 2-inch pipe, wall, or panel mounting bracket. Route field wiring through dedicated conduit entries using approved cable glands to maintain the IP66 ingress protection seal. Terminate twisted-shielded pair cables at the internal screw terminals, ensuring the cable drain wire bonds directly to the single-point cabinet safety ground bar. Verify correct 24 VDC polarity and line loop resistance limits before closing the enclosure cover and applying power to the loop.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43917228867674,"sku":"P0901XT-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/371._9fbd3058-7193-4510-8b83-618a17c02c5f.jpg?v=1787795124","url":"https:\/\/www.spareoil.com\/products\/foxboro-p0901xt-02-evo-intelligent-transmitter-modules","provider":"SpareOil Automation","version":"1.0","type":"link"}