{"product_id":"foxboro-p0916kh-p0916kh-0b-i-a-series-termination-assemblies","title":"Foxboro P0916KH P0916KH-0B I\/A Series Termination Assemblies","description":"\u003ch2\u003eFoxboro P0916KH I\/A Series Termination Assembly\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro P0916KH\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eP0916KH-0B\u003c\/strong\u003e Termination Assembly, operates as a dedicated hardware component for wiring termination and field signal routing within Foxboro I\/A Series DCS networks. It accepts up to 24 channels of field wiring to interface 4-20 mA, RTD, thermocouple, and discrete signals directly to paired Fieldbus Modules (FBMs). The assembly maintains galvanic isolation between field conductors and system logic buses while executing signal conditioning across industrial loops.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0916KH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro (Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard Termination Assembly footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Foxboro I\/A Series TA mounting footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive field terminal interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels Supported\u003c\/td\u003e\n\u003ctd\u003eUp to 24 channels (FBM dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, RTD, Thermocouple, Discrete Signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between field wiring and logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eRemovable terminal blocks (spring clamp or screw type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Capacity\u003c\/td\u003e\n\u003ctd\u003e18 to 22 AWG copper conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard 35 mm DIN rail or panel baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCold Junction Compensation \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro P0916KH\u003c\/strong\u003e incorporates onboard cold junction compensation (CJC) temperature sensors directly adjacent to thermocouple terminal blocks. This architecture compensates for ambient thermal gradients across field connections, eliminating thermoelectric potential errors prior to signal digitization by host FBM units. Combined with channel-to-channel galvanic isolation paths, the assembly prevents ground loop currents, suppresses industrial common-mode noise, and maintains signal integrity for low-millivolt input loops across process control networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the P0916KH termination assembly require active configuration software or field calibration?\u003c\/p\u003e\n\u003cp\u003eA: No, the assembly is a hardware connection interface and does not require calibration. Signal scaling and channel configuration are managed directly within the host Foxboro I\/A Series DCS software tools upon assignment to the corresponding FBM module.\u003c\/p\u003e\n\u003cp\u003eQ: Can terminal wiring be serviced without disconnecting individual field conductors?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the unit utilizes removable terminal block assemblies (spring clamp or screw type) that allow field wiring harnesses (18 to 22 AWG) to remain wired during module replacement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the termination assembly chassis onto a standard 35 mm DIN rail or secure it to a panel baseplate inside a protective IP54 enclosure. Maintain a minimum vertical spacing of 50 mm above and below the block to support convection cooling and ensure adequate wire duct clearance.\u003c\/p\u003e\n\u003cp\u003eRoute low-voltage analog signal cables separately from high-voltage power lines. Strip field conductors to manufacturer specifications and secure them into the 18 to 22 AWG removable terminal blocks using standard torque limits. Connect cable shields to the dedicated cabinet ground bus at a single ground point to maintain galvanic isolation and suppress electromagnetic interference. Secure the interface cable linking the P0916KH termination assembly directly to the corresponding FBM baseplate port.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43931763474522,"sku":"P0916KH","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/358._640b2426-ec05-43b6-878b-d8f4e3861dd8.jpg?v=1787907746","url":"https:\/\/www.spareoil.com\/products\/foxboro-p0916kh-p0916kh-0b-i-a-series-termination-assemblies","provider":"SpareOil Automation","version":"1.0","type":"link"}