{"product_id":"foxboro-p0926kn-i-a-series-datasheet-technical-manual","title":"Foxboro P0926KN I\/A Series Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eFoxboro P0926KN I\/A Series FPM Power Cable\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro P0926KN\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eP0926KN\u003c\/strong\u003e Power Cable, operates as a dedicated hardware component for electrical power distribution within Foxboro I\/A Series platforms. Configured as a 3-pin to 3-pin Fieldbus Power Module (FPM) cable assembly measuring 60 inches (152 cm), the hardware provides direct physical\/electrical execution to route internal subsystem power across modular backplane segments.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0926KN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg (0.30 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eLength: 152 cm (60 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (determined by conductor current load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eFPM Power Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Configuration\u003c\/td\u003e\n\u003ctd\u003e3-pin to 3-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubsystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eFoxboro I\/A Series FPM \/ Baseplate architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, IEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Power Properties\u003c\/h3\u003e\n\u003cp\u003eThe cable assembly incorporates three independent insulated copper conductors optimized for low-impedance DC power transmission. This wiring architecture supports direct integration with Foxboro 4-20 mA HART loop protocol environments by delivering steady backbone voltage lines to baseplate modules while maintaining high-frequency noise attenuation. The physical shielding layer preserves structural channel-to-channel isolation parameters, blocking transient voltage spikes and cross-talk from migrating along parallel data communication paths.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this power cable be disconnected while the fieldbus system is fully energized?\u003c\/strong\u003e A: No, passive power cables must not be uncoupled under active load. Disconnecting the 3-pin connector while current is flowing can induce localized electrical arcing, disrupt redundant power supply rails, and cause data state degradation across adjacent hot-swappable modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the cable construction resist harsh industrial ambient environments?\u003c\/strong\u003e A: The cable insulation jacket is built to operate within temperature thresholds of -20 to +70 deg C. The polymer compound jacket resists physical deformation under localized thermal loading, mechanical bending stress, and chemical outgassing in standard control cabinet environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary function of the third pin in the connector assembly?\u003c\/strong\u003e A: The 3-pin layout assigns dedicated paths for positive and negative DC voltage feeds alongside a specific low-impedance chassis grounding route. This grounding path ensures continuous fault-current draining back to the primary enclosure panel earth grid.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Alignment and Insertion:\u003c\/strong\u003e Align the internal keyways of the 3-pin female connector with the matching male pins on the FPM or baseplate receptacle. Press linearly into position until the mechanical locking mechanism clicks completely into engagement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Constraints:\u003c\/strong\u003e Maintain a permanent physical bend radius of at least 50 mm along the 60-inch cable run. Do not force sharp 90-degree creases near the strain-relief boots to avoid internal wire stress or fatigue fractures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparation of Conductors:\u003c\/strong\u003e Route the power cable through designated low-voltage DC cabinet pathways. Separate this cable from high-voltage AC motor lines and high-current inductive switching devices by a minimum clearance of 30 cm to suppress external electromagnetic noise pickup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Continuity:\u003c\/strong\u003e Verify that the mating baseplate chassis possesses a direct low-impedance ground track to the master panel earth bus. This preserves the overall system shielding capabilities mapped through the cable assembly.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43463702151258,"sku":"P0926KN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/430._bff8cf50-29ef-4061-9264-fbef6951dc20.jpg?v=1780891068","url":"https:\/\/www.spareoil.com\/products\/foxboro-p0926kn-i-a-series-datasheet-technical-manual","provider":"SpareOil Automation","version":"1.0","type":"link"}