{"product_id":"gd10-a-yokogawa-centum-vp-fio-bus-interface-module","title":"GD10*A Yokogawa CENTUM VP FIO Bus Interface Module","description":"\u003ch2\u003eYokogawa GD10*A GD10 Series Bus Interface Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa GD10*A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eGD10A\u003c\/strong\u003e* Bus Interface Module, operates as a dedicated hardware component for high-speed serial data transmission within Yokogawa Field Integrated Operation platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGD10*A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard FIO Node Slot Format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.5 W (0.5 A at 5 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Support\u003c\/td\u003e\n\u003ctd\u003eESB Bus or Optical ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Distance\u003c\/td\u003e\n\u003ctd\u003eUp to 50 m copper \/ Up to 5 km optical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003e128 Mbps serial communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFIO Node Unit (ANB10\/ANR10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Signal Conditioning Profiles\u003c\/h3\u003e\n\u003cp\u003eThe GD10*A module maintains high-speed data exchanges between remote expansion nodes and central processing units over deterministic ESB bus lines. Ground loop currents across interconnected node racks cannot degrade signal integrity because internal isolation transformers provide 1500 VAC galvanic isolation between the bus interface and backplane logic. The module processes analog telemetry streams, including 4-20 mA HART loop protocol passes, while preserving channel-to-channel isolation parameters across downstream I\/O units. Furthermore, dynamic CJC routines maintain temperature measurement stability across linked thermocouple input modules without increasing network latency.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can engineering personnel extract or insert the GD10*A interface module while the node backplane remains energized?\u003c\/p\u003e\n\u003cp\u003eA: Personnel can hot-swap the module only if the target FCS cabinet utilizes redundant ESB bus configurations; removing a non-redundant module causes immediate communication loss to attached I\/O nodes.\u003c\/p\u003e\n\u003cp\u003eQ: How does the system handle signal loss across copper ESB bus lines extending near maximum length?\u003c\/p\u003e\n\u003cp\u003eA: The module applies internal differential signal amplification and error-checking algorithms to prevent noise interference over copper runs approaching the 50 m physical distance threshold.\u003c\/p\u003e\n\u003cp\u003eQ: What power rail energizes the internal logic of the GD10*A card?\u003c\/p\u003e\n\u003cp\u003eA: The module draws power directly from the internal 5 VDC backplane power bus provided by the host FIO node unit housing (ANB10 or ANR10).\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the module vertically into the designated bus interface slot of the ANB10 or ANR10 node unit until the locking mechanisms engage completely.\u003c\/li\u003e\n\u003cli\u003eVerify that optical fiber cables or shielded copper ESB cables maintain a minimum bend radius of 50 mm inside the cabinet raceways.\u003c\/li\u003e\n\u003cli\u003eGround the shield drain wire of copper ESB bus cables directly to the master functional ground bar to block electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eMaintain clean optical connectors using dedicated lint-free swabs before mating fiber lines to optical ESB transceiver ports.\u003c\/li\u003e\n\u003cli\u003eAlign cabinet layout planning to ensure unhindered vertical convection airflow around the node rack, keeping ambient temperatures within the -20 to +60 deg C operational envelope.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43881904504922,"sku":"GD10*A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/864..jpg?v=1787277459","url":"https:\/\/www.spareoil.com\/products\/gd10-a-yokogawa-centum-vp-fio-bus-interface-module","provider":"SpareOil Automation","version":"1.0","type":"link"}