{"product_id":"ge-ds200admah1a-analog-to-digital-module","title":"GE DS200ADMAH1A Analog-to-Digital Module","description":"\u003cp\u003eConfigured for analog signal digitization and digital DSP interfacing in LS2100 Static Starter Control platforms, the \u003cstrong\u003eGE DS200ADMAH1A\u003c\/strong\u003e (\u003cstrong\u003eDS200ADMA\u003c\/strong\u003e Analog-to-Digital Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200ADMAH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DS200 option board form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLogic bus powered via DSPC carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eLS2100 Static Starter Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eADMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManuals\u003c\/td\u003e\n\u003ctd\u003eGEH-6373, GEI-100218\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eUL, CE, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus LEDs\u003c\/td\u003e\n\u003ctd\u003eTwo: Green IMOK LED, Red FAIL LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003eThree channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Scaling\u003c\/td\u003e\n\u003ctd\u003e12-bit resolution, +\/-10 V into 2K ohm \/ 500 pF load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Interfacing\u003c\/td\u003e\n\u003ctd\u003eEPLD-registered discrete inputs to host DSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eXA_ (60-pin high-density), XB_ (40-pin high-density), TBPL (60-pin ribbon header)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus \u0026amp; Network I\/O Specifications\u003c\/h3\u003e\n\u003cp\u003eThe board mounts directly onto the DS200DSPC Digital Signal Processor card as an option module, extending high-velocity signal conversion capabilities across the backplane bus interface. Onboard EPLD logic registers discrete digital input signals and routes them directly to the DSPC processor, enabling real-time adaptive signal control for silicon-controlled rectifiers (SCRs). High-density multi-pin connectors (XA_, XB_) and the TBPL ribbon header maintain deterministic signal pathways, while full firmware flash compatibility is governed by the host DSP motherboard architecture.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the DS200ADMAH1A interface physically with the host DSP processor card?\u003c\/p\u003e\n\u003cp\u003eA: The board mounts as an option card on the DS200DSPC Digital Signal Processor card using three onboard high-density connectors: XA_ (60-pin), XB_ (40-pin), and TBPL (60-pin ribbon cable header).\u003c\/p\u003e\n\u003cp\u003eQ: What output drive capability and resolution do the analog channels provide?\u003c\/p\u003e\n\u003cp\u003eA: Four scaled analog channels drive a 500 pF load up to +\/-10 V into a 2K ohm impedance with 12-bit analog-to-digital resolution.\u003c\/p\u003e\n\u003cp\u003eQ: What indication do the onboard diagnostic LEDs provide during operation?\u003c\/p\u003e\n\u003cp\u003eA: The green IMOK LED illuminates to confirm normal operational status and active logic processing, while the red FAIL LED indicates a module hardware fault or communication failure with the host DSP card.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower Isolation: Disconnect and lock out main supply power to the LS2100 Static Starter cabinet before opening the chassis or attempting module installation.\u003c\/li\u003e\n\u003cli\u003eAnti-Static Safeguards: Wear a grounded wrist strap attached to the metal enclosure frame to prevent ESD damage to sensitive EPLD logic and ADC components during handling.\u003c\/li\u003e\n\u003cli\u003eConnector Engagement: Align the 60-pin XA_, 40-pin XB_, and 60-pin TBPL headers carefully with the host DS200DSPC board before pressing firmly to seat pin connections cleanly without mechanical stress.\u003c\/li\u003e\n\u003cli\u003eMounting Security: Ensure all PCB retention standoffs and mechanical fasteners are fully secured to maintain grounding continuity and vibration immunity inside the drive enclosure.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43913757884506,"sku":"DS200ADMAH1A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/DS200ADMAH1A.png?v=1787715704","url":"https:\/\/www.spareoil.com\/products\/ge-ds200admah1a-analog-to-digital-module","provider":"SpareOil Automation","version":"1.0","type":"link"}