{"product_id":"ge-ds200pccag9acb-mark-v-power-connect-card","title":"GE DS200PCCAG9ACB Mark V Power Connect Card","description":"\u003cp\u003eThe \u003cstrong\u003eGE DS200PCCAG9ACB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200PCCA\u003c\/strong\u003e Power Connect Card, operates as a dedicated hardware component for SCR power bridge interfacing and power distribution within Speedtronic Mark V control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200PCCAG9ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg (0.56 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e406.4 x 254.0 x 254.0 mm (16.0 x 10.0 x 10.0 in shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLogic board control power (\u0026lt; 15.0 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmature Voltage Range\u003c\/td\u003e\n\u003ctd\u003e240 to 630 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum AC Input\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 600 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Compatibility\u003c\/td\u003e\n\u003ctd\u003eJ-Frame and M-Frame configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated leg fuses, leg reactors, and dedicated DC voltage snubbers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Transformer Support\u003c\/td\u003e\n\u003ctd\u003eSeparate or common bus transformer modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Type\u003c\/td\u003e\n\u003ctd\u003eNormal Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Coating\u003c\/td\u003e\n\u003ctd\u003eNormal Conformal Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus \u0026amp; Firmware Architecture\u003c\/h3\u003e\n\u003cp\u003eThe DS200PCCAG9ACB interfaces high-voltage SCR bridge loops directly with the low-voltage control rack, routing critical drive telemetry and trigger gating signals through multi-pin connectors to optimize backplane bus communication velocity. High-voltage isolation barriers separate the power bridge feedback nodes from signal processing networks, ensuring stable I\/O density scaling during regenerative load switching. Firmware flash compatibility and parameter synchronization are managed upstream by the primary Mark V drive processor core, enabling plug-and-play signal exchange without direct local firmware reprogramming.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the DS200PCCAG9ACB support hot-swapping while the power bridge is active?\u003c\/p\u003e\n\u003cp\u003eA: No. High surface voltages up to 630 VDC exist across the SCR power bridge interface. The entire drive panel and main AC feed must be isolated and discharged before removal or installation.\u003c\/p\u003e\n\u003cp\u003eQ: Can the DS200PCCAG9ACB be used in non-regenerative applications?\u003c\/p\u003e\n\u003cp\u003eA: The G9 grouping is specifically designed for regenerative drive operation with dedicated DC voltage snubbers, leg reactors, and leg fuses tuned for 240 to 630 VDC armature loops.\u003c\/p\u003e\n\u003cp\u003eQ: How does the board interface with the main power bus?\u003c\/p\u003e\n\u003cp\u003eA: The module accommodates both separate and common bus transformer configurations, routing incoming AC lines rated up to 600 V rms through protective snubber and reactor circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that all primary AC supply breakers and DC link power sources are opened, locked out, and verified zero-voltage prior to handling the board assembly.\u003c\/li\u003e\n\u003cli\u003eInspect all leg fuses, DC snubber networks, and ribbon cable headers for signs of thermal stress or mechanical damage before mounting.\u003c\/li\u003e\n\u003cli\u003eReconnect all power supply and control cables to their precise connector positions on the replacement board to prevent high-voltage misrouting.\u003c\/li\u003e\n\u003cli\u003eEnsure secure mechanical connection to frame standoffs to maintain proper chassis ground continuity and heat dissipation paths.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43868771844186,"sku":"DS200PCCAG9ACB","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/DS200PCCAG9A.jpg?v=1787132206","url":"https:\/\/www.spareoil.com\/products\/ge-ds200pccag9acb-mark-v-power-connect-card","provider":"SpareOil Automation","version":"1.0","type":"link"}