{"product_id":"ge-ex2000-power-supply-board-ds200expsg1acb","title":"GE EX2000 Power Supply Board | DS200EXPSG1ACB","description":"\u003cp\u003eConfigured for power regulation and current-limiting protection in GE EX2000 excitation systems, the \u003cstrong\u003eGE DS200EXPSG1ACB\u003c\/strong\u003e (\u003cstrong\u003eEXPS\u003c\/strong\u003e Power Supply Board) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eRevision Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDesignator Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase PCB Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS200\u003c\/td\u003e\n\u003ctd\u003eStandard GE EX2000 domestic baseline PCB layout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Acronym\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEXPS\u003c\/td\u003e\n\u003ctd\u003ePower Supply Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGroup Variant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG1\u003c\/td\u003e\n\u003ctd\u003eGroup 1 base product configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1st Functional Revision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eInitial functional design revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2nd Functional Revision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eSecondary functional design revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArtwork Revision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eBase circuit trace layout and artwork revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS200EXPSG1ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard EX2000 card weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard EX2000 full-height card size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBus-powered \/ Station battery input conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEX2000 Excitation System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Revisions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRevision 1: A, Revision 2: C, Artwork: B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOnboard current-limiting protection for station battery inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Processing Architecture\u003c\/h3\u003e\n\u003cp\u003eThe DS200EXPSG1ACB conditions and distributes internal supply voltages required for excitation control electronics. Integrated protection circuits suppress line transients and limit current flow when operating from auxiliary station batteries. The module generates isolated telemetry signals for AC and DC input power monitoring, maintaining backplane bus communication velocity and I\/O density scaling while preserving firmware flash compatibility across EX2000 system racks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What primary protection mechanism is built into the DS200EXPSG1ACB?\u003c\/p\u003e\n\u003cp\u003eA: The board features current-limiting protection circuits to prevent overcurrent damage when powered via station battery supplies.\u003c\/p\u003e\n\u003cp\u003eQ: How is operating power distributed to host system electronics?\u003c\/p\u003e\n\u003cp\u003eA: The module converts incoming source power and delivers regulated DC voltages directly across the enclosure backplane bus.\u003c\/p\u003e\n\u003cp\u003eQ: How are functional updates identified on this specific board version?\u003c\/p\u003e\n\u003cp\u003eA: Revision level is indicated by the suffix code, signifying functional revisions A and C with artwork layout B.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eCompletely isolate all primary AC supply sources and station battery inputs prior to removing or installing the board.\u003c\/li\u003e\n\u003cli\u003eConnect an ESD grounding wrist strap to an unpainted metal surface on the cabinet frame.\u003c\/li\u003e\n\u003cli\u003eSlide the board along the enclosure guide rails until the backplane connectors seat completely.\u003c\/li\u003e\n\u003cli\u003eTighten front panel retaining screws to ensure proper grounding and mechanical stability.\u003c\/li\u003e\n\u003cli\u003eRe-engage power to the cabinet only after confirming all interface harness connections are fully secured.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43874518040666,"sku":"DS200EXPSG1ACB","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/DS200EXPSG1ABB_23b1de6b-399b-4581-9319-e7bfff756cd5.png?v=1787216195","url":"https:\/\/www.spareoil.com\/products\/ge-ex2000-power-supply-board-ds200expsg1acb","provider":"SpareOil Automation","version":"1.0","type":"link"}