{"product_id":"ge-fanuc-ds200dtbcg1aaa-contact-output-termination-module","title":"GE Fanuc DS200DTBCG1AAA Contact Output Termination Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc DS200DTBCG1AAA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200DTBC\u003c\/strong\u003e Contact Output Termination Module, operates as a dedicated hardware component for relay output signal distribution and field wiring termination within Mark V Speedtronic systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200DTBCG1AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePower Supplied via System Interconnects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Blocks\u003c\/td\u003e\n\u003ctd\u003e2 Terminal Blocks (110 Signal Wire Terminals Each)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eJS1-JS8 (TCRA Relay Signals), J8 (TCPD Power Signal), J15 \u0026amp; J16 (125 VDC Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003e10 Onboard Hardware Jumpers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc DS200DTBCG1AAA\u003c\/strong\u003e interfaces directly with primary control core cards via multi-pin plug connectors to distribute contact output signals across the system backplane. Backplane bus communication velocity guarantees rapid transmission of relay command states without propagation lag. Firmware flash compatibility across connected controller cards ensures that physical contact output states align deterministically with software logic updates in the central processing rack.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What primary signal interfaces and connectors are populated on the DS200DTBCG1AAA?\u003c\/p\u003e\n\u003cp\u003eA: The board features 2 terminal blocks with 110 wire terminals each, 10 jumpers, JS1-JS8 connectors for TCRA relay signals, a J8 TCPD power connector, and J15\/J16 connectors for 125 VDC contact output power.\u003c\/p\u003e\n\u003cp\u003eQ: How do the onboard jumpers affect board configuration?\u003c\/p\u003e\n\u003cp\u003eA: The 10 hardware jumpers configure relay signal routing and voltage feedback paths between the termination board and upstream control cards.\u003c\/p\u003e\n\u003cp\u003eQ: What power sources must be isolated prior to replacing the DS200DTBCG1AAA module?\u003c\/p\u003e\n\u003cp\u003eA: Both main AC supply feeds and external 125 VDC contact power circuits connected to J15 and J16 must be isolated to ensure complete electrical safety during module replacement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e Open primary circuit breakers and pull fuses to de-energize all incoming AC power sources and external 125 VDC contact supply lines before servicing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Grounding:\u003c\/strong\u003e Wear an anti-static grounding wrist strap secured to an unpainted metal chassis frame during board handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Connection:\u003c\/strong\u003e Insert wire leads firmly into the designated 110-terminal blocks, verifying that terminal screws are torqued down to prevent loose high-current contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeader Cable Routing:\u003c\/strong\u003e Connect JS1-JS8, J8, and J15\/J16 header cables to their matching board connectors according to system schematics, ensuring header latches engage fully.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43895550312538,"sku":"DS200DTBCG1AAA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/DS200DTBCG1AAA.png?v=1787541645","url":"https:\/\/www.spareoil.com\/products\/ge-fanuc-ds200dtbcg1aaa-contact-output-termination-module","provider":"SpareOil Automation","version":"1.0","type":"link"}