{"product_id":"ge-fanuc-ds200fsaag2aba-field-supply-gate-amplifier-board","title":"GE Fanuc DS200FSAAG2ABA Field Supply Gate Amplifier Board","description":"\u003cp\u003eThe \u003cstrong\u003eGE DS200FSAAG2ABA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFSAA\u003c\/strong\u003e Field Supply Gate Amplifier Board, operates as a dedicated hardware component for gate drive pulse amplification and field current excitation within GE Mark V Speedtronic drive control racks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eRevision Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDesignator Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase PCB Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS200\u003c\/td\u003e\n\u003ctd\u003eStandard GE Mark V domestic baseline PCB layout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Acronym\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFSAA\u003c\/td\u003e\n\u003ctd\u003eField Supply Gate Amplifier Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGroup Variant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG2\u003c\/td\u003e\n\u003ctd\u003eGroup 2 functional circuit configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1st Functional Revision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eInitial functional design revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2nd Functional Revision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eSecondary functional design revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArtwork Revision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eBase circuit trace layout and silkscreen artwork revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS200FSAAG2ABA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBus-powered via internal rack connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpeedtronic Mark V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo 30 A, 60 V fast-acting fuses mounted in onboard fuse block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne 10-pin connector, four 2-pin connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJumpers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 Berg-type manually adjustable jumpers (JP1 to JP6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePCB Coating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormal Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Drive Processing\u003c\/h3\u003e\n\u003cp\u003eThe DS200FSAAG2ABA processes field excitation firing signals to drive power semiconductors while maintaining high-speed backplane bus communication velocity. Onboard hardware jumpers (JP1 through JP6) allow configuration between standard NRP default mode and alternate operational states. Integrated diagnostic test points permit real-time voltage monitoring without interrupting circuit continuity. Fast-acting 30 A, 60 V fuses protect gate amplification loops from overcurrent faults, preserving system operation and firmware flash compatibility across connected DIRECTO-MATIC and Mark V platforms.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the ratings and mounting types for the fuses on the DS200FSAAG2ABA?\u003c\/p\u003e\n\u003cp\u003eA: The board features two 30 A, 60 V fast-acting fuses seated in dedicated onboard fuse blocks for simplified field removal and replacement.\u003c\/p\u003e\n\u003cp\u003eQ: How are the onboard Berg-type jumpers configured from the factory?\u003c\/p\u003e\n\u003cp\u003eA: The jumpers (labeled JP1 through JP6) are factory-set to support standard NRP default operational mode.\u003c\/p\u003e\n\u003cp\u003eQ: What cable connectors are populated on the board surface?\u003c\/p\u003e\n\u003cp\u003eA: The board includes one 10-pin primary cable connector and four 2-pin secondary cable connectors for multi-channel signal distribution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eIsolate all main power lines and discharge field power circuits prior to removing or installing the card.\u003c\/li\u003e\n\u003cli\u003ePut on an ESD grounding wrist strap attached to the cabinet ground point before touching board components.\u003c\/li\u003e\n\u003cli\u003eVerify that jumper positions on JP1 through JP6 on the replacement card match the settings of the original board.\u003c\/li\u003e\n\u003cli\u003eSecure cable harness connectors onto the 10-pin and 2-pin headers, verifying correct orientation and keyway engagement.\u003c\/li\u003e\n\u003cli\u003eEnsure all field wiring drain wires are tied directly to the cabinet earth grounding bar using low-impedance pigtails to prevent noise interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43874460205146,"sku":"DS200FSAAG2ABA","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/DS200FSAAG2ABA.png?v=1787214073","url":"https:\/\/www.spareoil.com\/products\/ge-fanuc-ds200fsaag2aba-field-supply-gate-amplifier-board","provider":"SpareOil Automation","version":"1.0","type":"link"}