{"product_id":"ge-fanuc-ic200alg240-versamax-analog-input-module","title":"GE Fanuc IC200ALG240 VersaMax Analog Input Module","description":"\u003ch2\u003eGE Fanuc IC200ALG240 VersaMax Isolated Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-precision analog signal acquisition in VersaMax PLC platforms, the \u003cstrong\u003eGE Fanuc IC200ALG240\u003c\/strong\u003e (\u003cstrong\u003eIC200ALG240\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution. This module processes eight independent voltage and current input channels, transferring converted 16-bit digital values directly across the backplane bus to host processor units.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number \/ Matrix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSeries \/ Line\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eIsolation Level\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC200ALG240\u003c\/td\u003e\n\u003ctd\u003eIC200ALG240\u003c\/td\u003e\n\u003ctd\u003eVersaMax I\/O\u003c\/td\u003e\n\u003ctd\u003e8-Channel 16-Bit Analog\u003c\/td\u003e\n\u003ctd\u003eFull Channel-to-Channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc (Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11.0 cm x 6.68 cm x 5.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane: 15 mA max at 5 VDC; External: 100 mA max at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels (channel-to-channel isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-Bit (381 nA current \/ 381 uV voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Ranges\u003c\/td\u003e\n\u003ctd\u003e+\/-10 VDC, 0 to 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Ranges\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003eVoltage: \u0026gt;1 Mohm; Current: 250 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of full scale at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and Channel-to-Backplane (Galvanic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Deterministic Network Integrity\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG240 interfaces with the main controller via the high-velocity VersaMax backplane bus, drawing a minimal 15 mA current at 5 VDC. System logic receives updated 16-bit analog values every 16.7 ms at 60 Hz or 20 ms at 50 Hz filter settings. Channel-to-channel and channel-to-backplane galvanic isolation eliminates ground loops and limits cross-talk noise during high-density I\/O density scaling, maintaining signal fidelity across deterministic network architectures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the backplane current draw for the IC200ALG240 module?\u003c\/p\u003e\n\u003cp\u003eA: The module draws a maximum of 15 mA at 5 VDC directly from the VersaMax logic backplane bus.\u003c\/p\u003e\n\u003cp\u003eQ: How does channel-to-channel galvanic isolation affect module operation during field fault conditions?\u003c\/p\u003e\n\u003cp\u003eA: Full channel-to-channel galvanic isolation prevents ground potential differences and electrical faults on one channel from propagating to adjacent channels or compromising backplane logic circuits.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping supported for this module on the VersaMax carrier?\u003c\/p\u003e\n\u003cp\u003eA: Yes, operators can perform live module replacement on the active carrier base, provided field power is safely isolated prior to removal.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFollow these standardized procedures when installing and wiring the module in industrial panels:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eSnap the carrier base onto the standard DIN rail and ensure the mechanical latch firmly grips the rail.\u003c\/li\u003e\n\u003cli\u003eInsert the IC200ALG240 module vertically into the carrier connector until both side locking tabs click into position.\u003c\/li\u003e\n\u003cli\u003eWire signal lines using twisted-pair shielded cable, connecting shields to the terminal strip earth ground points to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eVerify that external 24 VDC field power (19.5 VDC to 30 VDC operating range) is correctly wired to the carrier power terminals.\u003c\/li\u003e\n\u003cli\u003eKeep signal wiring separated from high-voltage AC lines and motor drive outputs within wire ducting to maintain specified 16-bit measurement accuracy.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42870855532634,"sku":"IC200ALG240","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/195..jpg?v=1772241090","url":"https:\/\/www.spareoil.com\/products\/ge-fanuc-ic200alg240-versamax-analog-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}