{"product_id":"ge-fanuc-ic200alg262-versamax-analog-input-module","title":"GE Fanuc IC200ALG262 VersaMax Analog Input Module","description":"\u003cp\u003eConfigured for high-resolution single-ended analog current signal processing in VersaMax I\/O architectures, the \u003cstrong\u003eGE Fanuc IC200ALG262\u003c\/strong\u003e (\u003cstrong\u003eIC200ALG262\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution. The module converts 0-20 mA or 4-20 mA current loops across 8 single-ended input channels arranged in a single group, delivering digitized values directly to the central processing unit or network interface unit over the backplane bus.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 lbs (0.11 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot VersaMax module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e200 mA maximum at 5 VDC from PLC backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels (single-ended, 1 group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Resolution\u003c\/td\u003e\n\u003ctd\u003e15 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Resolution\u003c\/td\u003e\n\u003ctd\u003e0.5 uA for 4-20 mA; 0.625 uA for 0-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e100 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e7.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Range\u003c\/td\u003e\n\u003ctd\u003e-10 V to +10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e70 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Functions\u003c\/td\u003e\n\u003ctd\u003eLoss of internal user power, open wire detection (4-20 mA mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module executes backplane data transfers at deterministically scheduled scan cycles, updating all 8 analog channel values every 7.5 ms across the 5 VDC VersaMax system bus. Integrated Analog-to-Digital Converter (ADC) logic guarantees a constant 15-bit digital resolution across both 0-20 mA and 4-20 mA operating modes without processing overhead. Full backplane communication and configuration execution requires compatibility with VersaPro software Version 2.0 or higher, VersaMax PLC CPU Firmware 2.10 or higher, or Ethernet Network Interface Unit (NIU) firmware Version 1.10 or higher. Range selection relies on hardware jumpers: operating without a terminal jumper sets the default 4-20 mA range, whereas installing the jumper selects the 0-20 mA range.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the firmware requirements for operating the IC200ALG262 with a VersaMax CPU or NIU?\u003c\/p\u003e\n\u003cp\u003eA: The module requires VersaMax PLC CPU Firmware Version 2.10 or higher, or VersaMax Ethernet NIU Firmware Version 1.10 or higher, used alongside VersaPro software Version 2.0 or higher.\u003c\/p\u003e\n\u003cp\u003eQ: How is open wire fault detection handled across the input ranges?\u003c\/p\u003e\n\u003cp\u003eA: Open wire fault detection is active exclusively when the module is operating in the 4-20 mA range mode; loss of internal power diagnostics remains active across all modes.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum current drawn by the module from the backplane?\u003c\/p\u003e\n\u003cp\u003eA: The module draws a maximum current of 200 mA from the internal 5 VDC system backplane power supply.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSnap the module securely onto the VersaMax I\/O backplane carrier or DIN rail assembly before applying system power.\u003c\/li\u003e\n\u003cli\u003eEnsure terminal jumpers are installed or removed on the wiring base prior to field wiring according to the desired loop range (uninstalled for 4-20 mA, installed for 0-20 mA).\u003c\/li\u003e\n\u003cli\u003eConnect 8 single-ended field current loops using shielded twisted-pair cables to mitigate common-mode noise and external electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields to ground at the signal source end, or ground at the module base if source grounding is unavailable.\u003c\/li\u003e\n\u003cli\u003eVerify that the module OK LED illuminates green upon power-up to confirm valid backplane initialization and successful configuration loading.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43796911652954,"sku":"IC200ALG262","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC200ALG262.jpg?v=1786091084","url":"https:\/\/www.spareoil.com\/products\/ge-fanuc-ic200alg262-versamax-analog-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}