{"product_id":"ge-fanuc-ic200cbl001-versamax-programming-cable","title":"GE Fanuc IC200CBL001 VersaMax Programming Cable","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200CBL001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200CBL001\u003c\/strong\u003e Programming Cable, operates as a dedicated hardware component for point-to-point serial data transfer within VersaMax system networks. The cable provides an RS-232 connection between programming workstations and RS-232 Port 1 on the PLC controller.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200CBL001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.31 lbs (0.14 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15 m (50 ft) cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eUp to 80 deg C maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive physical media (30 V voltage rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eStraight-through RS-232 serial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003e9-pin D-sub male to 9-pin D-sub female (crimp style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 115,200 bps maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Specification\u003c\/td\u003e\n\u003ctd\u003e24 AWG copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eOverall electromagnetic interference (EMI) shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesignated Port\u003c\/td\u003e\n\u003ctd\u003eRS-232 Port 1 on VersaMax PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe serial cable facilitates hardware link execution at data transmission rates up to 115,200 bps without introducing physical latency over its 15 m length. The assembly utilizes 24 AWG copper conductors enveloped in a grounded shield layer to suppress signal cross-talk and ambient high-frequency noise. This physical media path ensures firmware flash compatibility and error-free bit-stream delivery during PLC CPU memory clearing, program downloading, and online logic execution monitoring via serial Port 1.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What connector types are constructed on the ends of the IC200CBL001 cable?\u003c\/p\u003e\n\u003cp\u003eA: The cable utilizes a 9-pin D-sub male connector on one end and a 9-pin D-sub female connector on the opposite end.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum baud rate supported by the cable assembly?\u003c\/p\u003e\n\u003cp\u003eA: The cable supports serial communication data rates up to a maximum of 115,200 bps.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IC200CBL001 cable incorporate noise shielding?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the cable incorporates an integrated shielding layer over 24 AWG copper conductors to prevent electromagnetic interference.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect both 9-pin D-sub connectors for bent pins or debris prior to attachment.\u003c\/li\u003e\n\u003cli\u003eConnect the cable directly to RS-232 Port 1 on the VersaMax PLC unit.\u003c\/li\u003e\n\u003cli\u003eAttach the opposite 9-pin connector to the serial port of the programming computer or serial converter.\u003c\/li\u003e\n\u003cli\u003eTighten connector jack-screws finger-tight to secure electrical contact and maintain ground continuity through the shield.\u003c\/li\u003e\n\u003cli\u003eRoute the 15 m cable away from high-voltage AC power lines and variable frequency drive output cables.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43796930429018,"sku":"IC200CBL001","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC200CBL001.jpg?v=1786092884","url":"https:\/\/www.spareoil.com\/products\/ge-fanuc-ic200cbl001-versamax-programming-cable","provider":"SpareOil Automation","version":"1.0","type":"link"}