{"product_id":"ge-fanuc-ic200mdd844-versamax-discrete-mixed-i-o-module","title":"GE Fanuc IC200MDD844 VersaMax Discrete Mixed I\/O Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200MDD844\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200MDD844\u003c\/strong\u003e Discrete Mixed I\/O Module, operates as a dedicated hardware component for discrete signal processing within VersaMax PLC backplane systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDD844\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Various\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.17 kg (0.38 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaMax module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e70 mA at 5 VDC backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal I\/O Count\u003c\/td\u003e\n\u003ctd\u003e32 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 points (2 groups of 8), positive logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 points (1 group of 16), sourcing\/positive logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10.2 to 30 VDC (0.5 A per point at 30 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn\/Off Response Time\u003c\/td\u003e\n\u003ctd\u003e0.5 ms default (configurable filters: 0 ms, 1 ms, 7 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Integration \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module communicates over the VersaMax backplane bus at a operating potential of 5 VDC, transferring high-density input and output states directly into the CPU image table. Internal logic buffers field input channels using configurable hardware filtering options (0 ms, 1 ms, or 7 ms) to eliminate mechanical contact bounce and electromagnetic interference before transmitting deterministic data across the system bus. Firmware flash compatibility across the VersaMax family ensures direct alignment with system controllers, while solid-state switching execution maintains microsecond-level response times for critical output loads without physical contact wear.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the backplane power supply limitations when deploying this high-density I\/O module?\u003c\/p\u003e\n\u003cp\u003eA: The module draws 70 mA from the 5 VDC backplane supply rail. Total backplane load calculations must account for this draw alongside other attached VersaMax expansion modules to prevent voltage drop across the carrier logic bus.\u003c\/p\u003e\n\u003cp\u003eQ: How do input filter settings affect field signal execution speed?\u003c\/p\u003e\n\u003cp\u003eA: The default input filter time is 1 ms, providing standard signal stabilization. Disabling the filter achieves a rapid 0.5 ms response time, whereas selecting a 7 ms filter provides maximum noise rejection in high-interference industrial field environments.\u003c\/p\u003e\n\u003cp\u003eQ: What hardware revision is required for 12 V negative logic output operation?\u003c\/p\u003e\n\u003cp\u003eA: Standard IC200MDD844 hardware operates with 10.2 to 30 VDC positive\/sourcing logic. Applications requiring 12 V negative logic output execution require upgrading the hardware module to revision IC200MDD844C or later.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier Terminal Connection\u003c\/strong\u003e: Insert the module firmly into its designated VersaMax snap-in I\/O carrier until the retaining latch engages fully with the backplane bus structure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation and Routing\u003c\/strong\u003e: Route field input wiring and 24 VDC output load lines in separate wiring channels away from high-voltage AC lines to prevent inductive coupling into digital channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding\u003c\/strong\u003e: Ensure the I\/O carrier DIN rail is grounded to the cabinet protective earth terminal with low-impedance copper braid. Terminate external sensor cable shields at a single chassis grounding point near enclosure entry.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43833253625946,"sku":"IC200MDD844","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC200MDD842_88235f88-ed30-4c9c-90c6-918247c04596.png?v=1786523908","url":"https:\/\/www.spareoil.com\/products\/ge-fanuc-ic200mdd844-versamax-discrete-mixed-i-o-module","provider":"SpareOil Automation","version":"1.0","type":"link"}